Unique Broadband Systems Ltd. DRU1KW User Manual

Page of 176
 
 
Chapter 2 
System Description 
 
2.6 
Power Supply 
 
Power Supply 
Voltage 
190 – 264 VAC (208 VAC nominal), 
Single Phase, 4 wire (L1, L2, N, G) 
Frequency 
47 to 63 Hz 
Power Consumption 
Overall: max. 19.2 kVA 
HB Cabinet: 10.1 kVA 
LB Cabinet: 9.1 kVA 
 
 
2.7 
Environmental 
 
Environmental 
Ambient Operating Temperature 
-4°F to +131°F (-20°C to +55°C) 
Ambient Storage Temperature 
-22°F to +167°F (-30ºC to +75ºC) 
Operating Humidity 
5% to 95%, non-condensing 
Storage Humidity 
5% to 99%, non-condensing 
Altitude 
max. 5500 ft. (1676 m) 
Electronics Compartment Cooling 
Air-to-Air Heat Exchanger 
Electronics Compartment 
Inside Temperature 
14°F to +149°F (-10°C to +65°C) 
HPA Compartment Cooling 
Forced Air, 2800 CFM 
HPA Compartment 
Inside Temperature 
-4°F to +131°F (-20°C to +55°C) 
Total DRU Heat Dissipation 
54,000 BTU (Exhausted + Radiated) 
Note: Radiated heat (into room) is equal to 
15% of dissipated heat. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SX03-20000-01-M01 2-5