 Chapter 
Installation 
 
3.16  AC Power 
 
3.16.1  General Requirements 
 
A certified Electrician should connect the repeater to the building/site electrical service panel 
to meet all local and national electrical codes, and according to the repeater electrical 
drawing(s). 
 
  AC Supply Voltage: 190 – 264 VAC (208 VAC nominal), Single Phase 
  Frequency: 47 to 63 Hz 
  Power Consumption: 19.1 kVA max. 
 
 
Verify that the AC supply voltage is within the specified range and check 
all power cables for damage. 
 
 
3.16.2  Repeater Cabinet Ground Connection 
 
 
The repeater cabinets must be connected to the building/site’s main 
ground terminal. 
 
An external ground conductor can be secured to the ground stud located on the left side of 
the HB cabinet using the 
XX nut
 – see Figure 3-41.  
A torque rating of XX In. Lbs. should be 
used to tighten the nut.
 
 
An external ground conductor can be secured to the ground stud located on the right side of 
the LB cabinet using the 
XX nut
 – see Figure 3-42.  
A torque rating of XX In. Lbs. should be 
used to tighten the nut.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 