SR-uSOM-MX6 Power Up Sequence 
Integration with the SR-uSOM-MX6 is easy, power sequencing wise. Note the following 
requirements: 
 
The MicroSOM internal power management contains a soft-start clamp that gradually 
raises its internally generated power supplies once VIN_5V0 is applied. The soft-start 
timing is set to be 800us (typ.). SNVS_3V0 must be applied well ahead of the internal 
power rails. We recommend that SNVS_3V0 be applied no later than 200uS after 
VIN_5V0. 
 
SNVS_3V0 must be applied before NVCC_EIM0, NVCC_SD2 and NVCC_SD3. 
Alternatively, SNVS_3V0 can be shorted with those power supplies as long as they do 
not exceed 3.3v (absolute maximum including overvoltage ripples). 
Notice the HummingBoard design, where there is a single 3.2V power rail generated 
from the 5V DC IN (either via LDO or external DC-DC), and that rail is directly applied to 
VSNVS_3V0, NVCC_EIM0 together with the VIN_5V0.