Zenner Performance Meters Inc d.b.a. Zenner USA WM2F User Manual

Page of 13
 
 
 
 
Stealth Reader MIU User’s Manual Rev 17A 
Copyright 2017, Zenner USA 
 
 
 
Page 5                 
       
 
Confidential 
Procedure 
Connecting to the Register 
The Stealth Reader is wired directly to the meter.  The following table matches the type of Register and the wires 
that need to be connected for each type.  Follow the instructions in the Connection Techniques Section at the end 
of the chart.  If the wiring is not per the chart, the Stealth Reader will not work properly with the meter.  Some 
Registers will have screw terminals.  The screws will be labeled with either the word or the starting letter of the 
colors, for example “R, G, B, etc.”. 
   
 
Stealth Reader MIU to Register Wiring 
 
Brand 
Model 
Register Type 
SR Wires 
Register Wires 
Zenner 
ETR / ETRU 
Encoded 
Red 
Red 
 
 
 
Green 
Green 
 
 
 
Black 
Black 
 
 
 
 
 
ABB/Kent 
Scancoder 
Encoded 
Red 
Green 
 
 
Type 2 
Green 
Red 
 
 
 
Black 
Black 
 
 
 
 
 
Hersey 
Translator 
Encoded 
Red 
Red 
 
 
Type 16 
Green 
Green/White 
 
 
 
Black 
Black 
 
 
 
 
 
Master Meter 
Dialog 
Encoded 
Red 
Green 
 
 
 
Green 
Green 
 
 
 
Black 
Red 
 
 
 
 
 
Metron 
Prolink 
Encoded 
Brown 
Red 
 
 
 
White 
Green 
 
 
 
Black 
Black 
 
 
 
 
 
Neptune 
T-8 
Encoded 
Red 
1 Post 
 
 
 
Green 
2 Post 
 
 
 
Black 
3 Post