6.5.1 
Environmental Conditions 
Operating temperature 
*)
 
-
20 … +50 °C within 1 week 
-
20 … +45 °C within 1 week 
-
20 … +40 °C within 6 week 
-
20 … +35 °C within 1 week 
Operating temperature 
-5 ... +30 °C 
Humidity 
0-85 %, non-condensing 
EMC stability 
in accordance with EN 61000-6-2: Noise immunity (industrial area) 
EN 61000-6-4: noise emission 
increased requirements in accordance with IEC 62061 
Vibration tolerance 
EN 60068-2-6 
EN 60721-3-7 
2-9 Hz: amplitude 3.5 mm 
9-200 Hz: 1 g (10 m/s²) 
200-500 Hz: 4g (40 m/s²) 
Shock resistance 
EN 60068-2-27 
EN 61131-2 
15 g 
Protection type 
EN 60529 
Protection type through unplugged housing - factory condition IP20  
Protection type connected with MS 031 - operating condition
1
: IP34 
 
*) 
Since the function  occurs through a  chemical reaction in the battery, it  is considered  a chemical product. As such, 
the battery performance will decrease over time. Even if it is placed unused in storage over a long period of time. In 
addition, various conditions of use such as charging, discharging, ambient temperature, etc. will reduce the lifespan of 
the battery or the device in which the battery is used can be damage be electrolyte leakage. 
 
 
6.5.2 
Miscellaneous 
Article number 
01-810-021 
Hardware version 
2.x 
 
                                                           
1
 