 MIFARE
Data sheet V 1.00 5E9030.29
19
5.6 MIFARE commands - Examples
write,a,0,5,0123456789ABCDEF0123456789ABCDEF
Response:
Command write ->   
Data in sector 1 Block 5 written=0123456789ABCDEF0123456789ABCDEF
read,a,0,5
Response:
Command read ->
Data in block 5 in HEX=0123456789ABCDEF0123456789ABCDEF
Initzero,a,0,8
Response:
Command initzero ->
Data in sector 2 Block 8 written=00000000FFFFFFFF0000000000FF00FF
Incr,a,0,8,8,2
Response:
Command incr ->
Block 008 successful by 0000000002 incremented and written to block 008
read,a,ff ff ff ff ff ff,5
Response:
Command read ->
Data in Block 5 in HEX=FFFF0000000000000000000000000000
connect,0b a1 78 98
Response:
Command connect ->
***************INFO***************
Key_mode = Key_eeprom
Info_text = Info_on
Tag_connected = Manual_mode
Tag_sn = 0BA17898
***********END_OF_INFO************
read_blocks,a,0,0,3
Response:
Command read_blocks ->
Data in block 0 in HEX=3B7CF4E05388040046B9949745302809
Data in block 1 in HEX=00000000000000000000000000000000
Data in block 2 in HEX=00000000000000000000000000000000
Data in block 3 in HEX=000000000000FF078069FFFFFFFFFFFF