Installing and Connecting the AKL08RF Zigbee Zone Wiring Centre
Use the AKL08RF  zone wiring centre to simply and safely connect thermostats and corresponding thermal actuators or motorised valves. The AKL08RF connects to the wireless network through the AC10RF 
coordinator or the Universal Gateway SG888ZBWH. One coordinator can support up to nine wiring centres, which means that if you buy more than one wiring centre, you will only need one of the 
included coordinators. Keep the other coordinators in a safe place as spares.  If you are using the Universal Gateway SG888ZBWH please remove the AC10RF coordinator from your system. 
Install the AKL08RF only in dry and closed interior rooms. Relative air humidity in the room may not exceed 95%. Clean the AKL08RF only with a dry and soft cloth. Do not use solvents or aggressive cleaning agents.
If you are not using  theSG888ZBWH 
Gateway then plug in the AC10RF 
coordinator.
LED indications
Name 
Colour               Meaning
Power
AKL08RF is supplied with 120V power
G1 
 
Wireless network activity on group 1 thermostats
G2 
 
Wireless network activity on group 2 thermostats
Network Status 
 
AKL08RF is waiting to pair 
 
AKL08RF is connected to the wireless network 
Zone 1 actuators 
 
Demand from group 1, zone 1 thermostat: actuator open
Zone 2 actuators 
 
Demand from group 1, zone 2 thermostat: actuator open
Zone 3 actuators 
 
Demand from group 1, zone 3 thermostat: actuator open
Zone 4 actuators 
 
Demand from group 1, zone 4 thermostat: actuator open
Zone 5 actuators 
 
Demand from group 2, zone 1 thermostat: actuator open
Zone 6 actuators 
 
Demand from group 2, zone 2 thermostat: actuator open
Zone 7 actuators 
 
Demand from group 2, zone 3 thermostat: actuator open
Zone 8 actuators 
 
Demand from group 2, zone 4 thermostat: actuator open
Pump 
 
Pump on
Boiler 
 
Boiler on
 
CO 
 
Heating Mode
 
 
Cooling Mode
Set the boiler delay, wireless, and thermal 
actuator jumpers.
Jumper Settings/Positions for Pump/Boiler
On/Off Delay
The pump/boiler on delay and the pump 
off delay are fixed 3 minutes in the software 
and at 0 in the terminal. The default setting 
for the boiler off delay is also 0 minutes, 
but can be changed to 15 minutes. 
To do this, carefully remove the jumper and 
re-insert it in the other position as shown below:
Wireless
The default setting for the wireless connection 
is internal (INT). If the external antennae A8RFA 
is used change this setting (EXT). Carefully 
remove the jumper and re-insert it in the other 
position as shown below:
Type of Actuator
The default setting for the type of actuator is 
normally closed (NC). To change this setting 
to normally open (NO), carefully remove the 
jumper and re-insert it in the other position as 
shown below. Note that the actuator setting 
and thermostat setting must be the same.
Push in the Dew Point 
wires in the AKL08RF 
for a dry contact 
humidity sensing.
Bend and place the wires into their
correct positions.
Reattach the 24V supply connection.
Bend and place the wires into the
round holes at the button of the
AKL08RF for actuators/motorised
valves. You can add up to 4 actuators
or motorised valves for each zone.
Reattach the white cover to the
wiring center and secure it with two
screws.
Make sure there is the correct
fuse (4 Amp).
Re-attach the plastic cover. Turn the 
screw in the lock position. Switch on 
main power supply to the unit. The red 
LED comes on.
Re-attach the High voltage cover and 
secure it with two screws.
Coordinator
Connecting the AKL08RF (s) to the ZigBee Wireless Network
1. On powering up the AKL08RF, all actuator  LEDs light up green then go off, then the  Network Status LED flashes green.
2. Press and hold the button on the coordinator for five  seconds. The button  flashes red to indicate the coordinator is
ready to pair. The Network Status LED on the AKL08RF goes steady green when  connected.
3. Repeat the process for every AKL08RF in the system. Note that one  coordinator can support up to nine AKL08RFs.
4. To identify your AKL08RF  (WC)  number press Pair for one second. The LED on the zone number lights green:
Zone 1 = WC -1, Zone 2 =  WC-2, and so on. The Network Status LED is used to identify WC-9.
5. To pair your Salus thermostats, see your thermostat  manual.
6. Press the coordinator button for five seconds until the LED flashes  steady red.
Note: To restore the AKL08RF back to factory default settings at any time, using a suitable tool, press the Reset button to the left 
of the pair button.
Checking the System Configuration and Communication
• Press and hold the coordinator button for one second. All devices  connected to the system flash. To stop checking, press and hold the coordinator 
button again for one second.
• Press and hold the Pair button on the WC for five seconds. All devices  connected to the AKL08RF will flash. To stop checking, press and hold  the Pair
button again for five seconds.
Deleting all Devices from the Wireless Network
•   To delete all devices connected to the network, press and hold the  coordinator button for 15 seconds. The colour of the button changes  from red
to amber.
•  To delete all devices connected to the AKL08RF, press and hold  the pair button on the AKL08RF for 15 seconds. The  G1  and G2 LEDs turn from flashing 
red to solid red then go off.
Note: After all devices have been deleted from the wireless network, they will need to be reinstalled. Refer to the instruction manuals.
Universal Gateway
Connecting the AKL08RF (s) to the ZigBee Wireless Network
1. On powering up the AKL08RF, all actuator  LEDs light up green then go off, then the  Network Status LED flashes green.
2. Remove the coordinator, access the Wise.ly App and add your AKL08RF. When in Pairing Mode, the Universal Gateway will start flashing red. The Network  
Status LED on the AKL08RF goes steady green when  connected.
3. Repeat the process for every AKL08RF in the system. Note that  one Universal Gateway can support up to 100 devices
(thermostats, ARV’s, etc.).
4. To identify your AKL08RF  (WC)  number press Pair for one second. The LED on the zone number lights green:
Zone 1 = WC -1, Zone 2 =  WC-2, and so on. The Network Status LED is used to identify WC-9.
5. To pair your Salus thermostats, see your thermostat  manual.
6.  The Universal Gateway will turn solid blue automatically, once the pairing process is complete.
Note: To restore the AKL08RF back to factory default settings at any time, using a suitable tool, press the Reset button
to the left of the pair button.
Checking the System Configuration and Communication
• Go to the Wise.ly App and press the Identify button. The device will start flashing. Stop the identify process by pressing
the button from the App again.
• Press and hold the Pair button on the WC for five seconds. All devices  connected to the AKL08RF will flash. To stop 
checking, press and hold  the Pair button again for five seconds.
Deleting all Devices from the Wireless Network
•  You can remove your devices from the Wise.ly App. Equipment, All equipment menu.
•  To delete all devices connected to the AKL08RF, press and hold  the pair button on the AKL08RF for 15 seconds. The  G1  and G2 LEDs turn from flashing 
red to solid red then go off.
Note: After all devices have been deleted from the wireless network, they will need to be reinstalled. Refer to the instruction manuals.
 Antenna protective cap 
Connect your wiring center to
a 120VAC supply
Connect the wires to the correct terminals.
3
Warning
 
Use the powercord connections that are 
suitable for your system.
5
7
8
9
10
11
12
13
Clip in the terminals for boiler and pump 
connection. Press the terminal button, 
insert the cable and release the button.
Ensure the Pump and Boiler wires are placed in 
their respective grooves in the back plate.
4
i
Make sure to put the wires through
the grooves.
24
VAC
6
24
VAC
Push in the CO wires 
for  dry contact 
heating/cooling 
changeover switching. 
An open switch is for 
heating (red LED). A 
closed switch is for 
cooling (blue LED).
Heating mode
Cooling mode
A.  Remove the plastic cover by turning the
screw 90o to the Unlock position. 
B.  Remove the High voltage cover.
C.  Detach the 24V supply connection .
D.  Remove the white terminal for access to the  
power cord connections.
E.   Insert wires for the Power, Pump and Boiler  
and fasten securely.
F.  Use the proper wire connectors (purchased  
separately) for a 120VAC power supply  
system. After placing the wires through the  
wire  connectors, secure them by 
 
tightening the screws.
A.
B.
D.
E.
C.
1
F.
2
Attach the back of the AKL08RF to the wall or
in a suitable location.
110mm/4.33in
Pump
100mm/3.93in
Actuator or Motorised valve
Power 120V 
www.salusna.com  Technical Helpline 1-650-360-1725
If you need to install the specified 
external antenna and have set the 
 
wireless jumpers to EXT:
a. Disconnect power.
b. Remove the protective cap 
from the antenna  connection 
on the bottom of the  AKL08RF/
SAA6MI1.
c. Screw the antenna into the 
AKL08RF/SAA6MI1.
d. Change the INT/EXT jumper  position
to EXT position.
e. Reconnect power. The  AKL08RF
/SAA6MI1  will now
  use the
external  antenna and not the
 internal antenna.
i
The antenna (type A8RFA, gain 2.15dBi, made by 
Salus ) for AKL08RF
/SAA6MI1 is sold separately.
110mm/4.33in