Valeport Ltd 0804IDU User Manual

Page of 83
 
HydrINS 2 / HydrINS 2 Mini flow meter  
Installation Manual  
Page 9 / 83 
2.1  Measurement Principle  
The velocity measurement principle is based on the application of Faraday's Law, which states that a 
voltage is generated by the movement of a conductor through a magnetic field.  
In the case of HydrINS 2/HydrINS 2 Mini, the magnetic field is generated by a coil at the end of the 
probe,  and  the  water  passing  through  the  pipe,  whose  conductivity  must  be  at  least  20  µS/cm
represents the conductor. 
The  electromotive  force  generated  by  the  passage  of  the  water  through  the  magnetic  field, 
comparable to a voltage, is measured by the two electrodes, which are visible on both sides of the 
stem. Because this electromotive force is proportional to the velocity, the HydrINS 2/ HydrINS 2 Mini 
probe  carries  out  a  velocity  measurement  derived  from  the  electromotive  force  of  the  water.  The 
flow rate is then deduced from this velocity measurement. 
The  electromagnetic sensor is located at the tip of the  insertion rod. It has an exciter coil and two 
electrodes, seen on the side of the sensor. 
 
Figure 1: Location of the sensor on the HydrINS2/HydrINS 2 Mini flow meter 
Probe head and guide bar 
Insertion stem 
Electrodes 
Sensor