USER MANUAL 
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 
to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  pro-vide  reasonable  protection  against  harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and 
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may 
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to 
cause harmful interference in which case the user will be required to correct the interference at his own expense.   
15.21 Statement - for all intentional and unintentional radiators. 
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s 
authority to operate the equipment. 
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation 
 
TE Connectivity 
2801 Fulling mill road 
m/s 106-19 
Middletown, PA – 17057 
Phone: (717) 564-0100 
 
The “TE-2G4-RFZB_telgo100m” module is a ZigBee RF transceiver. It would typically be used in a fixed 
system as part of a smart-relay circuit in industrial facilities. 
Note: prior to setting a mode, the channel of operation can be set. 
Receive mode (Rx mode): Receive packets from a compatible ZigBee transceiver 
Transmit mode (TxPackets mode): Transmits a designated set of packets.   
 
Additional transmit mode (not under normal operation) include: 
1. 
TxTone mode: Transmitting a continuous carrier frequency. 
2. 
TxStream mode: Transmitting a continuous stream of random symbols. 
 
1.  Click “START” 
Feedback will be provided in the message window. 
2.  Click “INITIALIZE” 
Feedback will be provided in the message window. 
3.  Set CHANNEL by using UP or DOWN arrow. Low channel = 11. 
Mid Channel =18. High Channel =25.   
Feedback will be provided in the message window each time. 
4.  For NORMAL operation transmission mode, click on “TX PACKETS”. 
Feedback will be provided in the message window. 
4b. For CONTINUOUS TX STREAM click on “TX STREAM”.