Melnor Inc. 3300-1 User Manual

Page of 1
The Melnor AquaSentry™ works in 
conjunction with Melnor’s AquaTimers™ 
to provide complete watering manage
-
ment for your lawn or garden. Place the 
sensor in the area you ar
e watering and 
set the desired moistur
e level. Then 
attach the receiver to your timer
. The 
AquaSentry™ will prevent watering 
when it is not needed and end 
watering when your desired level 
has been reached. It’
s that simple. 
The result is healthy grass and 
plants while saving money and 
conserving water.
Melnor, Inc.
3085 Shawnee Drive
Winchester, V
A 22601
540-722-5600
100 Summerlea Road
Brampton, Ontario L6T 4X3
905-792-9330
www.melnor
.com
0
42
20
6
33
00
5
5
1. Changes or modifications not expressly appr
oved by Melnor, Inc. could 
void the user's authority to operate the equipment.
2. This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide r
easonable protection against harmful interfer
ence in a 
residential installation. This Equipment generates, uses and can radiate radio 
frequency ener
gy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. 
However there is no guarantee that interfer
ence will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by tur
ning the equipment off 
At Melnor, we’re 
committed to the 
responsible use of one 
of the world’s most 
precious resources. 
We continue to 
introduce innovative 
products that help you 
conserve water while 
maintaining healthy 
lawns and gardens.  
Through our dedication 
and our products, we 
give you the tools you 
need to Be Water 
Wise. We believe that 
with dedication and 
our creative products 
we can all learn to
Be Water Wise.
Caution:
1. Residential use only. Not intended for commer
cial applications.
2. Intended for outdoor use only.
3. Severe electrical shock could r
esult if water is 
  
  sprayed into outlets or sour
ces of electrical current.
4. Do not use water over 115° F (46° C).
Model
33005
Complete Watering Management Set
TM
n
  Melnor AquaTimer™ included
n
  View entire program at a glance
n
  Easy to set
Wireless Moisture Sensor
n
 Automatically Water When 
   You Want
n
 Monitor the Soil to Maintain   
   Desired Moisture Level
n
 Save Water, Time and Money
Patent Pending
Complete Watering Management Set
Wireless Moisture Sensor
TM
Setting Up Your AquaTimer
®
Install the Battery
Tool required:  Phillips head screwdriver.
Remove screws and lift off the battery cover. You may need to use the 
screwdriver to gently pry off the battery cover. Insert one 9V battery 
and replace battery cover and screws. Make note of the positive and 
negative contacts.
Attaching the Timer to the Faucet
NOTE: Your AquaTimer
®
 can be programmed on or off the faucet. 
It may be easier to program the timer first and then attach it.
Simply attach the top coupling nut to the faucet by twisting the nut clock- 
wise. The nut should be snug. Do not overtighten. Once the AquaTimer
®
 is 
attached, turn on the faucet and leave it on while the timer is attached. 
Remember to turn off the water when you need to remove the AquaTimer
®
.
Attach a garden hose to the outlet end of the timer and then set up a 
sprinkler as you normally would.
Setting the Timer
1.  Use left arrow to decrease and right arrow to increase numbers (        ) 
  to set “Current Time” to nearest hour at that time, noting AM and PM. 
2.  Repeat above instructions to set ”Start Time” to desired time of day  
  to begin watering.
3.  Use left and right (        ) arrow buttons to set “How Often” (watering  
Welcome to the world of Melnor
®
 watering innovation.  Thank you for 
choosing the Melnor
®
 AquaSentry™ Wireless Moisture Sensor.  With the 
AquaSentry™, you will avoid unneeded and wasteful watering while 
protecting the health and beauty of your valuable lawn and garden.
The AquaSentry™ is an innovative device that automatically monitors 
the amount of moisture in the soil and then prevents your Melnor
®
 
AquaTimer
®
 from activating if there is already enough moisture present.  
Additionally, once watering has begun, AquaSentry™ will continue to monitor 
the soil and end watering early if the desired 
moisture level is achieved.  
AquaSentry™ works with Melnor
®
 AquaTimer
®
 
models 3015 and 3060 that bear  the “Wireless 
Ready” logo.  Follow the AquaTimer
®
 
instructions to program your timer as you 
normally would.  AquaSentry™ will 
automatically override the program when 
no watering is needed. 
  frequency) to select an hour or day increment. (8 hours = 3 times per  
  day, 2 days = every other day)
4.  Use left and right (        ) arrow buttons to set “How Long” (watering  
  duration) to select a minute or hour increment.
5.  Activate the watering program by pressing the Program On/Off button; 
  a horizontal bar will be displayed to signify the program is on. Press 
  the Program On/Off button again to disable the program.
NOTE: To avoid accidentally changing the current program, the arrow 
buttons will be “locked out” or inaccessible if “Program On” is selected.
To create a new program, press Program On/Off button if necessary to 
disable the current program. Press (        ) arrow buttons to desired 
settings and press Program On/Off button again to select the newly 
created program.
To avoid watering during the current program, press the Program On/Off 
button to disable the program and press again to enable the program 
when desired.
Watering Manually
Press the Manual On/Off button to water manually. Press the button 
again to stop watering; otherwise the timer will water for 30 minutes and
automatically shut off.
Low Battery
A fresh battery should last one watering season. When the battery is 
weak, the low battery indicator bar will show. If this occurs during a 
watering program, the unit will automatically shut off and discontinue 
running the program. The valve will not reopen until a fresh battery is 
installed. After inserting a new battery, the timer must be re-programmed 
to resume watering. 
LCD Sleep Mode
To prolong battery life, the LCD will “sleep” after approximately 4 minutes of 
button inactivity. “Wake” the unit by pressing either the Program On/Off or 
the Manual On/Off buttons.
Setting Up Your AquaSentry
®
Install the Batteries
Tool required:  Phillips head screwdriver.
Remove the two  small screws and remove the battery cover. Insert two 
(2), fresh AA batteries.  Please note the positive (+) and negative (–) ends of 
the batteries and ensure they are inserted correctly following the markings 
inside the battery compartment.
Replace the battery cover and screws.  A fresh set of quality 
batteries should last a full watering season or about nine months.
Place the Moisture Sensor
CAUTION:  Never use a hammer or any other tool to 
pound the unit into the ground.  Do not attempt to 
force the unit into the ground. This will damage the 
Sensor. The AquaSentry™ has a maximum wireless 
range of 200 feet (60 meters). The Sensor must be 
placed within the area you are watering.  For best 
operation, place the Sensor in direct sight of the 
Timer/Receiver.  The Sensor can be placed out of 
direct site of the Timer/Receiver, but the range may 
be diminished somewhat.
To insert the Sensor, first dig a pilot hole about the 
same size as the probe.  The hole must be deep 
Continue to monitor your particular watering requirements based on 
weather conditions and overall plant health.
Attach the Receiver to the Timer
Slide the receiver onto the rail along the top 
of your compatible Melnor® AquaTimer®.  
The receiver does not need to slide fully on 
to work properly.  You may need to leave a 
gap to allow for operation of the faucet.
Connect the Receiver cable to the socket 
located on the bottom of your AquaTimer®.  
Note the orientation of the three (3) pins to 
be certain the cable is attached correctly.
t u
t u
t u
t
u
enough to bury the entire sensor probe.  (Illustration)  Remove any large 
rocks or other debris from the soil that is removed from the hole.  Place 
the Sensor into the hole so that the entire probe is under ground level.  
The face of the Sensor unit should be turned toward the Timer/Receiver. 
Return the soil to the hole and pack firmly into place. It is important that 
the entire front surface of the probe be in contact with the soil.
Selecting the Desired Moisture Level
Individual grass and plant species have varying moisture requirements. 
The AquaSentry™ Moisture Sensor has three moisture settings plus OFF.  
Melnor® recommends initially setting the knob to the medium setting 
(two droplets).  After a week, you should reassess the moisture in the area 
you are watering.  If the soil is too wet, adjust the unit to the dryer setting 
(one droplet).  If the soil is too dry, select the wetter setting (three droplets).  
Sprinkler and hose not included.
Requires (1) 9V & (2) AA batteries.
After installing the receiver, press either the “Program” or “Manual” 
button once to wake the timer. If the AquaSentry™ system is working 
properly, an antenna symbol should appear 
as shown (Illustration…3015 and 3060) 
within 35 seconds indicating communication 
between the Sensor, Receiver and 
AquaTimer®.   If the symbol displays 
steadily, your AquaSentry™ is working 
properly and monitoring the soil’s moisture 
level.
If the antenna symbol is flashing, one of the 
following has occurred:
 
a. The batteries in the moisture sensor are not installed  
 
    properly or they are too weak.
 
b. The Moisture Sensor is out of range.
If the antenna symbol fails to appear, the connection between the 
Receiver and the AquaTimer® is faulty.
Check all of the above.  Wait for 5 minutes or until the AquaTimer® 
display turns off.   Then wake the AquaTimer® and watch for the 
antenna symbol.  The antenna symbol should appear within 35 seconds.
Over time, if the antenna symbol begins to flash, the batteries in the 
Sensor are weak and need to be replaced. 
Be Water
Wise!
and on, the user is encouraged to try to correct the interfer
ence by one or 
more of the following measur
es:
.. Reorient or relocate the r
eceiving antenna.
.. Increase the separation between the equipment and the r
eceiver.
.. Connect the equipment into a differ
ent outlet or a circuit dif
ferent fr
om that  
 to which the r
eceiver is connected.
.. Consult the dealer or an experienced radio/TV technician for help.
3. This device complies with Part 15 of the FCC Rules. Operation is subject 
to the following two conditions: (1) this device may not cause harmful 
interference, and (2) this device must accept any interfer
ence received, 
including interference that may cause undesir
ed operation.
TM