Huntkey V-Power 400 LW-6400HGP User Manual

Product codes
LW-6400HGP
Page of 5
2.3 Output protection
    If the power supply is latch into shutdown stage (when OCP ,OVP or 
short protection is working ),the power supply shall return to normal 
operation only after the fault has been removed and remote signal must 
reset for a minimum of 1 second (or the AC removed for 10 second) . 
Then, it will turn on again.
2.3.1 Over Voltage Protection (OVP)
    In case of over voltage limits are exceeded, the power supply shall 
provide latch-mode over-voltage protection. 
+5V
50mVp-p
2.2 Output Ripple & Noise
Ripple & Noise
+3.3V
50mVp-p
PSU
07
PSU
08
V-POWER
V-POWER
V-P ower 550
Voltage
Max. load
Min. load
+3.3V
25A
0.3A
+12V1
18A
1.0A
+5V
20A
0.5A
-12V
0.8A
0A
+12V2
18A
1.0A
+5VSB
2.5A
0A
+3.3V&+5V total output not exceed 130W 
Output watt: 450W 
Max. Output Capacity: 550W
2.3.2 Short Circuit Protection (SCP)
    An output short circuit is defined as any output impedance of 
less than 0.1 ohms. The power supply shall shut down and latch 
off for shorting all output to GND.
2.3.3 Over Current Protection (OCP)
    Overload currents are applied to each tested output rail. If the 
current limits are exceeded, the power supply shall shutdown and 
latch off.
    If you have any questions or need any supports, please contact 
your reseller, the nearest Huntkey agent or Huntkey headquarter 
service center. 
+12V1,2,3,4
120mVp-p
-12V
120mVp-p
+5VSB
50mVp-p