Canary CFT-2067SA User Manual

Page of 5
Fast Ethernet Copper-to-Fiber Converters
CFT-206X – Standard multi-mode & single-mode series: 100BASE-TX to 100BASE-FX
Ordering Information
Fast Ethernet
Media
Min. Tx
Max. Tx
Rx
Min. PWR
Max.PWR
Max. Input
Connector
Wavelengths
Transmit
Model Numbers
Types
PWR
PWR
Sensitivity
Budget
Budget
PWR
Type
(ηm)
Distance
CFT-2061
UTP / MM
-20.0 dBm
-14.0 dBm
-31.0 dBm
11.0 dB
17.0 dB
-8.0 dBm
SC
1310 ηm
2000 m
CFT-2062
UTP / MM
-20.0 dBm
-14.0 dBm
-31.0 dBm
11.0 dB
17.0 dB
-8.0 dBm
ST
1310 ηm
2000 m
Specifications above in blue are for multi-mode, fiber connectors.
   Specifications below for single-mode, fiber connectors.
CFT-2081-SM
UTP / SM
 -16.0 dBm
  -9.0 dBm
  -34.0 dBm
  18.0 dB
  25.0 dB
 -7.0  dBm
SC
1310 ηm
18 Km
CFT-2061-SM
UTP / SM
 -15.0 dBm
  -8.0 dBm
  -34.0 dBm
  19.0 dB
  26.0 dB
 -7.0  dBm
SC
1310 ηm
30 Km
CFT-2062-SM
UTP / SM
 -15.0 dBm
  -8.0 dBm
  -34.0 dBm
  19.0 dB
  26.0 dB
 -7.0  dBm
ST
1310 ηm
30 Km
CFT-2061-LSM
UTP / SM
-5.0 dBm
0.0 dBm
-35.0 dBm
30.0 dB
35.0 dB
0.0 dBm
SC
1310 ηm
50 Km
CFT-2061-XL
UTP / SM
-5.0 dBm
0.0 dBm
-35.0 dBm
30.0 dB
35.0 dB
0.0 dBm
SC
1550 ηm
80 Km
CFT-2061-E85
UTP / SM
-5.0 dBm
0.0 dBm
-35.0 dBm
30.0 dB
35.0 dB
0.0 dBm
SC
1550 ηm
80 Km
*NOTE 1:  All CFT models are available as uni-Directional  (D)  versions, that allow one-way traffic e.g. CFT-2061D.  For special order, contact Canary for information.
* NOTE 2:  Most versions of CFT-20XX standalone converters are available as card modules for Canary’s CCM-1600 and CCN-2000 / CCN-0400 Chassis models.
Please refer to the CCM-1600 and CCN-2000 / CCN-0400 Data Sheets s for more information.
More versions of the CFT-206X series may be found on the Canary web site as they become available.
Standard CFT-206X multi-mode converters provide transmission
distances of 2000 meters over 62.5/125 µm fiber.
Standard CFT-206X-SM single-mode models provide transmission
distances ranging from 30 to 80 kilometers over 9.0 µm single-
mode fiber.
Switch for Hard-Setting Full-Duplex or 100BASE-TX
Autonegotiation for 100 Mbs, Full and Half-duplex operation
Internal Auto-sensing, MDI / MDI-X crossover switch for
proper Network Interface Card or Switch connections
Switch enabled Link Fault Signaling (LFS) – Forwards lost
link awareness to each connected host
A full array of diagnostic LEDs
Auto-sensing, 100 / 240 VAC Power Supply
Optional:  UK, Continental European power
Unidirectional fiber transmission versions available for
sensitive security applications.
Additional models include: Single-Fiber Bi-Directional single-
mode and versions launching ITU specified CWDM transmitter
wavelengths
Illustrated: Standard Fast Ethernet Copper-to-Fiber Converter