takeMS Mini SD 512Mb MS512SDC-SD1 Leaflet

Product codes
MS512SDC-SD1
Page of 1
      
 
 
 
 
 
 
 
 
 
1. 
S: Power supply / I: input / O: Output using push-pull drivers / PP: I/= using push-pull drivers 
2. 
The extended DAT Lines (Dat1-Dat3) are input on power up. They start  to operate as Dat lines after SET_BUS_WIDTH command. The Host shall keep 
its own Dat1-Dat3 lines in input mode, as well, while they are not used. It is defined so, in order to keep compatibility to MultiMedia Cards. 
3. 
After power up this line is input with 50Kohm pull-up (can be used for card detection or SPd mode selection). The pull-up should be diconnected by user, 
during regular data transfer, with SET_CLR_CARD_Detect (ACMD42) command.
 
 
 
 
        Power Consumption 
• 
Read: <30mA 
• 
Write: <30mA 
• 
Standby: <100uA 
 
 
Bestell-Nr.:/Order No.: 
MSXXXSDC-SD1 
 
 
 
 
                          SD Mode 
SPI Mode 
Pin 
Name 
Type  
Description 
Name 
Type 
Description 
 
 
 
 
 
 
 
CD/DAT3² 
I/O/PP³  Card Detect/Data Line  
CD 
Chip Select (Active Low) 
 
 
 
Bit3 
 
 
 
CMD 
PP 
Command/Response 
DI 
I/PP 
Data In 
VSS
1
 
Supply Voltage Ground 
VSS 
Supply Voltage Ground 
VDD 
Supply Voltage 
VDD 
Supply Voltage 
CLK 
Clock 
SCLK 
I  
Clock 
VSS
2
 
Supply Voltage Ground 
VSS
2
 
Supply Voltage Ground 
DAT0 
I/O/PP 
Data Line (Bit 0) 
DO 
O/PP 
Data Out 
DAT1 
I/O/PP 
Data Line (Bit 1) 
RSV 
 
 
DAT2 
I/O/PP 
Data Line (Bit 2) 
RSV 
 
 
10 
NC
4
 
I/O/PP 
For Future Use 
NC 
 
For Future Use 
11 
NC
4
 
I/O/PP 
For Future Use 
NC 
 
For Future Use 
Physical Dimension Specifications (Units in mm) 
 
Type 
Measurement 
Length 
21,5mm+/- 0,1mm 
Width 
20,0mm+/- 0,08mm 
Thickness 
1,4mm+/- 0,1mm 
Weight 
1,0g max. 
                                  Environment Specifications 
 
Type 
 
Standard 
Temperature  Operating  
-25°C to 85°C 
 
Non-Operating  -40°C to 85°C 
Humidity 
Operating  
8% to 95%, non-condensing 
 
Non-Operating  8% to 95%, non-condensing 
Vibration 
Operating  
15G peak-to-peak Max. 
 
Non-Operating  15G peak-to-peak Max. 
Shock 
Operating  
1000G Max. 
 
Non-Operating  1000G Max. 
Altitude 
Operating  
80.000 feet Max. 
 
Non-Operating  80.000 feet Max.