Spaun SBK 5503 NFI 842488 User Manual

Product codes
842488
Page of 176
127
www.spaun.com
contact@spaun.com
CA
TV
CA
TV
Model
Art. No.
HLV 40/30 FPE
813128
HLV 40/65 FPE
813129
EAN
4040326131282
4040326131299
Inputs / Outputs
1 / 1
1 / 1
Screening factor
> 85 dB
> 85 dB
Gain
47 ... 862 MHz / 40, 30, 20 dB
85 ... 862 MHz / 40, 30, 20 dB
Return path gain
5 ... 30 MHz / 20, 15, 10, 5 dB
5 ... 65 MHz / 20, 15, 10, 5 dB
Output level return path 
60 dB IMA
3
 / EN 60728-3
max. 110 dBμV
max. 110 dBμV
Output level forward path
60 dB IMA
3
 / EN 60728-3
max. 113 dBμV
max. 113 dBμV
Level adjusting range
0 ... -12 dB
0 ... -12 dB
Slope correction range
0 ... -16 dB
0 ... -16 dB
Noise figure
8 ... 9 dB
8 ... 9 dB
Noise figure return path
5 ... 7 dB
5 ... 7 dB
Mains power supply V~
100  ... 240 V / 47 - 63 Hz
100  ... 240 V / 47 - 63 Hz
Power consumption max.
13 W
13 W
Ambient temperature
-20  ... +50 °C
-20  ... +50 °C
Dimensions (mm)
260 x 130 x 52
260 x 130 x 52
CATV and Line Amplifier
HLV 40/30 FPE, HLV 40/65 FPE
•   Active and passive return path
•  For medium sized distribution systems
•  External test ports (-30 dB) at input and output
•  LED indicator for power supply
•  Metal / plastic housing for indoor mounting
•  Protection class IP 20
Multiple functionality
Return path selectable:
off - passive - active.  
Gain selectable:  
20, 15, 10 or 5 dB
Return path
Forward path
15 dB
passiv
10 dB
20 dB
5 dB
off
20 dB
40 dB
30 dB
Integrated attenuator and 
slope control
0 ... -12 dB
0 ... -16 dB
Energy Saving
Switch-Mode Power Supply
Energy