Spaun SBK 5503 NFI 842488 User Manual

Product codes
842488
Page of 176
146
www.spaun.com
Measur
ement
Measur
ement
No.
DiSEqC
TM
commands
Option
Monitor
Voltage
22 kHz
continous 
tone
ToneBurst
Bus
Monitor
A
B
< 15 V > 15 V 22 kHz
1
E21038F0
on
off
Vert. L.A.
13
0
0
on
off
off
Vert. L.A.
2
E21038F2
on
off
Hor. L.A.
18
0
0
off
on
off
Hor. L.A.
3
E21038F1
on
off
Vert. H.A.
13
1
0
on
off
on
Vert. H.A.
4
E21038F3
on
off
Hor. H.A.
18
1
0
off
on
on
Hor. H.A.
5
E21038F4
on
off
Vert. L.B.
13
0
1
on
off
off
Vert. L.B.
6
E21038F6
on
off
Hor. L.B.
18
0
1
off
on
off
Hor. L.B.
7
E21038F5
on
off
Vert. H.B.
13
1
1
on
off
on
Vert. H.B.
8
E21038F7
on
off
Hor. H.B.
18
1
1
off
on
on
Hor. H.B.
9
E21038F8
off
on
Vert. L.A.
10
E21038FA
off
on
Hor. L.A.
11
E21038F9
off
on
Vert. H.A.
12
E21038FB
off
on
Hor. H.A.
13
E21038FC
off
on
Vert. L.B.
14
E21038FE
off
on
Hor. L.B.
15
E21038FD
off
on
Vert. H.B.
16
E21038FF
off
on
Hor. H.B.
Useful test tool and Bus-Monitor to ease systematic 
troubleshooting in distribution networks and for function check.
•  Loads and terminations of the networks do not    
 
change by using the test tool
New features:
•  Address indicator
•  Identification of the reply from the target 
 
device by DiSEqC 2.0 commands
•  Display of transmission errors
•  Test jack for LNB-Power and voltage
DiSEqC-Monitor
TP 216
Model
Art. No.
TP 216
871521
EAN
4040326715215
Frequency range
5 ... 2200 MHz
Through loss
2 dB
Test jack
-20 dB
DC-pass max.
600 mA
Power requirements
10 ... 20 V DC / 70 mA
Ambient temperature
-20  ... +50 °C
Dimensions (mm)
77 x 90 x 31
No.
Address 
Byte
Address LEDs
10
14
15
18
1
10
on
off
off
off
2
14
off
on
off
off
3
15
off
off
on
off
4
18
off
off
off
on
5
optional
on
on
on
on
By sending the DiSEqC-commands E00002, the Standby-LED turns on and by sending the Power-On command 
E00003 the Standby-LED turns off.
If the receiver sends DiSEqC 2.0 commands, the target devices have to confirm the reception of these commands. 
The reply of the target device will be displayed by the Reply-LED (9).
A transmission error in the DiSeqC-Protocol will be displayed by the LED „Parity-Error“ (10).
Function List
Tech-Hint