Coarse Wavelength Division Multiplexing
Optical Insertion Losses
Optical Insertion Loss estimation:
• Example 5 of Return-path link (Loss) calculation that considers
the Origin and two intermediate, OADM (client Drop, Add and
Pass-Thru) stages – assumes one λ per Drop point.
• Calculates typical and maximum Return-path Losses from furthest
(2nd) OADM (client Add/Drop-point) to Origin.
Table (C-5)
Insertion Loss: Each
Insertion
Insertion
Insertion
Acc. Loss
Insertion
Insertion
Insertion
Acc. Loss at
Total Loss at start-
Mux + De-Mux stage
Loss (1st)
Loss (1st)
Loss (1st)
at (1st)
Loss (2nd)
Loss (2nd)
Loss (2nd)
(2nd) Drop
point Demux w/ one
(typically at segment
 Drop point
Add point
Pass-Thru
Drop point
Drop point
Add point
Pass-Thru
point
Add (return) stage &
end-points)
one Pass-Thru stage
(M
O
 & D
O
)  (M
R
 & D
R
)
(C)
(B)
(E)
(M
O
 + C)
(F)
(G)
(H)
(M
O
 + E + F)
(G + E + D
O
)
1.2 dB            1.2 dB
1.0 dB
1.0 dB
0.5 dB
2.2 dB
1.0 dB
1.0 dB
0.5 dB
2.7 dB
2.7 dB
(Typical Optical Loss)
2.4 dB            2.4 dB
1.4 dB
1.4 dB
1.0 dB
3.8 dB
1.4 dB
1.4 dB
1.0 dB
4.8 dB
4.8 dB
(Maximum Optical Loss)
• Given: Origin Multiplexer/De-Multiplexer (CM-4MD6-A) losses
(M
O
 & D
O
) plus two OADM points & losses (C, B, E) and (F, G,
H) in the optical path.  The Remote site (Mux/De-Mux) is ignored
for this calculation example.