1. Input Characteristics:  
1.1 Input Voltage Range --- 100~240Vac, full range with active power factor 90% min  
   1.2 Input Frequency Range --- 47Hz to 63Hz.
1.3 Input Ac Current ( Max ) --- 8.0A max, full load. 
1.4  Inrush Current --- At 132Vac / 264Vac, full load condition,  
      no damage occur, input fuse shall not blow.
   1.5 Efficiency ---70% min, at nominal line input full load.
   1.6 Input Leakage Current  --- Leakage current from line to ground 
         will be less 10mA rms, measurement will be made at 240Vac/60Hz.  
2. Output Characteristics: 
2.1  Static Output Characteristics. 
 Output 
Voltage 
Load Range 
Min.        Max. 
 Regulation 
Min.        Max. 
Ripple Max  
mV P-P 
Ripple & Noise
 Max.  mV P-P
 
1. 
+3.3  V 
0.5 A
20.0 A 
 
- 5 % 
+ 5 %
50 mV 
100  mV 
 
 
2. 
+5.0  V 
0.3 A
30.0 A 
 
- 5 % 
+ 5 %
50 mV 
100  mV 
 
 
3. 
+12.0  V 
1.0 A
25.0 A 
 
- 5 % 
+ 5 %
100 mV 
150  mV 
 
 
4. 
-5.0  V 
0.0 A
 0.5 A 
 
- 10 %
+ 10 %
150 mV 
200  mV 
 
 
5. 
-12.0  V 
0.0 A
 0.5 A 
 
- 10 %
+ 10 %
150 mV 
200  mV 
 
 
6.  SB +5.0  V 
0.0 A
  3.0 A 
 
- 5 % 
+ 5 %
100 mV 
100  mV 
 
   Note:  
1.  Noise Test --- Noise bandwidth is from Dc to 20MHz. 
2.   Ripple frequencies greater than 1 MHz shall be attenuated by the  
                 measurement system. 
3.   Add 0.1uF / 10uF capacitor at output connector terminals for ripple & 
                 noise measurements. 
           4.  Combined total power from +3.3V and +5V rails shall not exceed 150W. 
           5.  The total output power shall not exceed 350W. 
2.2  Dynamic Output Characteristics: 
         2.2.1 Initial Delay Time --- NONE. 
         2.2.2 Rise Time --- 50 mS max, at nominal line full load.