Telegärtner H06000A0001 User Manual

Page of 368
Fiber Optic Components
C
FO Ready-to-install Fiber Optic Links
13
Telegärtner Karl Gärtner GmbH  •  Tel: +49-(0)7157 / 1 25-100  •  www.telegaertner.com
234
13.4
FO Simplex Cables
OS2
OM2
OM3
OM4
OM1
Standards
Standard
 ITU G.652 D 
(low water peak, 
≥ 15 mm)
 IEC60793-
2-10
 IEC60793-
2-10
 IEC60793-
2-10
 IEC60793-
2-10
Mechanical Characteristics
Calbe structure acc. DIN/VDE 0888
I-K(ZN)H …
I-K(ZN)H …
I-K(ZN)H …
I-K(ZN)H …
I-K(ZN)H …
Cable diameter
2,8/1,8
2,8/1,8
2,8/1,8
2,8/1,8
2,8/1,8
Max. pulling tension short-term/long-term in N: Ø 2,8
200 / 100
200 / 100
200 / 100
200 / 100
200 / 100
Max. pulling tension short-term/long-term in N: Ø 1,8
140 / 70
140 / 70
140 / 70
140 / 70
140 / 70
Max. Crush resistance in N/m
5000
5000
5000
5000
5000
Min. bending radius short-term/long-term
15x Ø
15x Ø
15x Ø
15x Ø
15x Ø
Colour of outer jacket
yellow
orange
orange/aqua
orange
orange
Weight in kg/km: Ø 2,8
7,2
7,2
7,2
7,2
7,2
Weight in kg/km: Ø 1,8
3,2
3,2
3,2
3,2
3,2
Climatic Characteristics
Operating temperature
-5 / +55
-5 / +55
-5 / +55
-5 / +55
-5 / +55
Storage temperature
-30 / +70
-30 / +70
-30 / +70
-30 / +70
-30 / +70
Installation temperature in °C
 -5 / +50
 -5 / +50
 -5 / +50
 -5 / +50
 -5 / +50
Flame retardancy
 IEC 60332-1
 IEC 60332-1
 IEC 60332-1
 IEC 60332-1
 IEC 60332-1
Halogen-free
 IEC 60754-2
 IEC 60754-2
 IEC 60754-2
 IEC 60754-2
 IEC 60754-2
Optical Characteristics
Fiber Class acc. to ISO/IEC 11801
OS2
OM2
OM3
OM4
OM1
Max. attenuation in dB/km at 850/1300 nm
-
2,8 / 0,90
3,0 / 1,0
3,0 / 1,0
3,2 / 1,1
Max. attenuation in dB/km at 1310/1550 nm
0,50 / 0,30
-
-
-
-
Bandwidth in MHz x km at 850/1300 nm
-
600 / 1200
1500 / 500
6000 / 500
200 / 600
Dispersion in ps/nm x km
≤ 3,5 / ≤ 18
-
-
-
-
Link Class OF in m at 1310/1550 nm: 1 Gbit/10 Gbit
10000 / 10000
-
-
-
-
Link Class OF in m at 850 nm: 1 Gbit/10 Gbit
-
600 /82
900 / 300
900 / 550
275 / 33
Link Class OF in m at 1300 nm: 1 Gbit/10 Gbit
-
600 /n.a.
550 / n.a.
550 / n.a.
550 / n.a.
Technical Characteristics
Application
 Patch cords
 Patch cords
 Patch cords
 Patch cords
 Patch cords
 
–
Order no.
Fiber type
Cable diameter
Pulling tension short-
term/long-term in N
Cable Colour
Weight
L08000A0005
E9/125 OS2
Ø 2,8 mm
≥200 / ≥100
yellow
9,1
L08000A0006
E9/125 OS2
Ø 1,8 mm
≥140 / ≥70
yellow
3,2
 
–
Order no.
Fiber type
Cable diameter
Pulling tension short-
term/long-term in N
Cable Colour
Weight
L08001A0002
G50/125 OM2
Ø 2,8 mm
≥200 / ≥100
orange
9,1
 
–
Order no.
Fiber type
Cable diameter
Pulling tension short-
term/long-term in N
Cable Colour
Weight
L08001A0005
G50/125 OM3
Ø 2,8 mm
≥200 / ≥100
orange
9,1
 
–
Order no.
Fiber type
Cable diameter
Pulling tension short-
term/long-term in N
Cable Colour
Weight
L08002A0002
G62,5/125 OM1
Ø 2,8 mm
≥200 / ≥100
orange
9,1
 
–
Order no.
Fiber type
Cable diameter
Pulling tension short-
term/long-term in N
Cable Colour
Weight
L08100A0001
S980/1000 POF
Ø 2,2 mm
≥15 / ≥5
schwarz
3,8
L08120A0000
S980/1000 POF
Ø 3,6 mm
≥60 / ≥10
orange
4,3