         2.2.3 Turn-on Delay Time --- 600mS max, at nominal line full load. 
         2.2.4 Hold-up Time --- 16mS min. for + 5V output at nominal line full load. 
         2.2.5 Transient Overshoot --- 10% max. of delay state after load change of 25% 
                   within the range of 50% to 100% of full load. 
         2.2.6 Temperature Coefficient --- 0.03% per 
qC
 max. 
3. Protections: 
   3.1 Over Voltage Protection --- Standard on +3.3V output set at 3.7Vdc – 4.5Vdc. 
                                                                                +5.0V output set at 5.7Vdc – 6.5Vdc. 
                                                                                +12.0V output set at 13.5Vdc – 14.5Vdc.   
3.2  Short Circuit Protection --- A short circuit placed between DC return and output 
                                                    shall cause no damage and the power supply shall 
                                                    shutdown. 
   3.3 Over Power Protection --- The power supply can use electronic circuit to limit the 
output.  Power against excessing +115% - 150% of full  load, or protected against 
excessive power delivery due to short circuit of any output or over total power.  
   3.4 No load Operation --- No parts damaged on power supply. 
4. Dielectric Withstand Voltage: 
4.1  Primary to Secondary -------- 1500Vac for 1 minute. Or 2200Vdc for 3 sec. 
   4.2 Primary to Safety Ground --- 1500Vac for 1 minute. Or 2200Vdc for 3 sec. 
   4.3 Insulation Resistance --------- Primary fo safety ground - 500Vdc, 100M ohms min. 
5. Conducted EMI: Internal Filter Can Meet. 
5.1  FCC Requirement --- Part15, SUB-Part J, Computing Devices “ Class B “ Limits.   
   5.2 VDE Requirement --- Class “ B “ ( General Operating Permit ) Requirements Of 
                                             VFG 234/1991.   
5.3  CISPR Requirement --- Class “ B “ Requirements Of CLSPR 22.   
   5.4 Harmonic Requirement --- IEC61000-3-2 & IEC61000-3-3  Class “ D “.