2.2.3 Turn-on Delay Time --- 600mS max, at nominal line full load.
2.2.4 Hold-up Time --- 16mS min. for + 5V output at nominal line full load.
2.2.5 Transient Overshoot --- 10% max. of delay state after load change of 25%
within the range of 50% to 100% of full load.
within the range of 50% to 100% of full load.
2.2.6 Temperature Coefficient --- 0.03% per
qC
max.
3. Protections:
3.1 Over Voltage Protection --- Standard on +3.3V output set at 3.7Vdc – 4.5Vdc.
+5.0V output set at 5.7Vdc – 6.5Vdc.
+12.0V output set at 13.5Vdc – 14.5Vdc.
+5.0V output set at 5.7Vdc – 6.5Vdc.
+12.0V output set at 13.5Vdc – 14.5Vdc.
3.2 Short Circuit Protection --- A short circuit placed between DC return and output
shall cause no damage and the power supply shall
shutdown.
shall cause no damage and the power supply shall
shutdown.
3.3 Over Power Protection --- The power supply can use electronic circuit to limit the
output. Power against excessing +115% - 150% of full load, or protected against
excessive power delivery due to short circuit of any output or over total power.
excessive power delivery due to short circuit of any output or over total power.
3.4 No load Operation --- No parts damaged on power supply.
4. Dielectric Withstand Voltage:
4.1 Primary to Secondary -------- 1500Vac for 1 minute. Or 2200Vdc for 3 sec.
4.2 Primary to Safety Ground --- 1500Vac for 1 minute. Or 2200Vdc for 3 sec.
4.3 Insulation Resistance --------- Primary fo safety ground - 500Vdc, 100M ohms min.
5. Conducted EMI: Internal Filter Can Meet.
5.1 FCC Requirement --- Part15, SUB-Part J, Computing Devices “ Class B “ Limits.
5.2 VDE Requirement --- Class “ B “ ( General Operating Permit ) Requirements Of
VFG 234/1991.
VFG 234/1991.
5.3 CISPR Requirement --- Class “ B “ Requirements Of CLSPR 22.
5.4 Harmonic Requirement --- IEC61000-3-2 & IEC61000-3-3 Class “ D “.