iStarUSA TC-750PD1 User Manual
+5V +3.3V +12V
1
+12V
2
+12V
3
+12V
4
-12V +5Vsb
1000uF
1000uF
2200uF
2200uF
2200uF
2200uF
NA
1uF
2.7 RISE TIME
20ms max at full load.
3.0 PROTECTION:
When OCP, OVP or short protection is triggered, the main outputs will be
latched off. The main outputs can be reset by cycling the DC remote on/off or AC
power. +5Vsb output is auto recovery when fault condition removed.
3.1 OVER CURRENT PROTECTION
+5V output: 55A max.
+3.3V output: 55A max.
+12V1~12V4 output: 35A max.
3.2 OVER VOLTAGE PROTECTION
+3.3V output
4.5 Vmax.
+5.0V output
7.0 Vmax.
+12.0V output 15.6 Vmax.
3.3 SHORT PROTECTION
All output to GND.
4.0 ENVIRONMENT:
4.1 OPERATING TEMP.
10
o
C to +50
o
C
4.2 STORAGE TEMP.
-20
o
C to +70
o
C
4.3 OPERATING HUMIDITY
20% to 90%, non-condensing
4.4 STORAGE HUMIDITY
5% to 95%, non-condensing
4.5 OPERATING ALTITUDE
0 to 10,000 feet
4.6 STORAGE ALTITUDE
0 to 50,000 feet