+5V +3.3V +12V
1
 +12V
2
 +12V
3
 +12V
4
 -12V  +5Vsb 
1000uF
1000uF
2200uF
2200uF
2200uF
2200uF
NA
1uF
2.7 RISE TIME
20ms max at full load. 
3.0 PROTECTION:
When OCP, OVP or short protection is triggered, the main outputs will be 
latched off. The main outputs can be reset by cycling the DC remote on/off or AC 
power.  +5Vsb output is auto recovery when fault condition removed. 
3.1 OVER CURRENT PROTECTION
+5V output: 55A max.
+3.3V output: 55A max. 
+12V1~12V4 output: 35A max. 
3.2 OVER VOLTAGE PROTECTION
+3.3V output 
4.5 Vmax. 
+5.0V output 
7.0 Vmax. 
+12.0V output   15.6 Vmax. 
3.3 SHORT PROTECTION
All output to GND. 
4.0 ENVIRONMENT:
4.1 OPERATING TEMP. 
10 
o
C to +50 
o
4.2 STORAGE TEMP. 
-20 
o
C to +70 
o
4.3 OPERATING HUMIDITY 
20% to 90%, non-condensing 
4.4 STORAGE HUMIDITY 
5% to 95%, non-condensing 
4.5 OPERATING ALTITUDE 
0 to 10,000 feet 
4.6 STORAGE ALTITUDE 
0 to 50,000 feet