Belkin PureAV Power Line Sniffer AP00002EA User Manual

Product codes
AP00002EA
Page of 8
Introduction:
This Sniffer demonstration unit is used to provide a visual and 
audible representation of AC-power-line noise that is detected within 
an 115VAC or 230VAC electrical circuit at 50/60Hz. 
Technical Specifications:
Input Power Supply:  
115VAC or 230VAC +/-10%; 50/60Hz
Operating Current:  
30mA max
Noise-Frequency 
Detection Range: 
100Hz to 2MHz
Operating Temperature:  
0° C to 40° C; Humidity: 0% to 90%
Dimensions:  
192.3 (L) x 100.6 (W) x 52.0mm (H)
Weight:  
0.7kg.
Operation Procedure:
Step 1:  Select Power-Supply Setting (Figure 1)
The default setting for the input power supply is 115V. If you are in 
a 230V power environment, please set the “power supply selection 
switch” to 230V. The input power-supply voltage (115V or 230V) will 
be visible directly on the switch for your verification. 
Caution: You must verify that the correct input power voltage is 
selected, or the unit will be damaged if the switch is not in the 
proper position.
 
Step 2:  Power-Supply Connection (Figure 1 and Figure 2)
Connect the included power cable to the Sniffer. Once the power 
cable is connected, the “Power On/Off” LED will illuminate and the 
liquid crystal display (LCD) will display the line-noise status. 
Note: To silence the loudspeaker, please press the “Sound” 
button once. 
1
P75338uk_AP00002uk.indd   4
28/12/06   11:49:35 am