Intel i5-2510E FF8062700853304 User Manual

Product codes
FF8062700853304
Page of 181
Datasheet
59
Thermal Management
A small amount of hysteresis has been included to prevent an excessive amount of 
operating point transitions when the processor temperature is near its maximum 
operating temperature. Once the temperature has dropped below the maximum 
operating temperature and the hysteresis timer has expired, the operating frequency 
and voltage transition back to the normal system operating point. This is illustrated in 
.
Once a target frequency/bus ratio is resolved, the processor core will transition to the 
new target automatically.
• On an upward operating point transition, the voltage transition precedes the 
frequency transition.
• On a downward transition, the frequency transition precedes the voltage transition.
When transitioning to a target core operating voltage, a new VID code to the voltage 
regulator is issued. The voltage regulator must support dynamic VID steps to support 
this method.
During the voltage change:
• It will be necessary to transition through multiple VID steps to reach the target 
operating voltage.
• Each step is 12.5 mV for compliant VRs.
• The processor continues to execute instructions. However, the processor will halt 
instruction execution for frequency transitions.
Figure 12.
Frequency and Voltage Ordering