PAN F Plus
 
 
 
Page 4 of 6
 
 
DEVELOPMENT TIMES
 
If PAN F Plus has been inadvertently exposed at 
settings below EI 25/15 or above EI 64/19, the 
following guide will ensure usable negatives are 
obtained. Obviously, the quality of negatives 
processed in this way will not be so high as 
conventionally processed ones.
 
 
Manual processing (min/20
o
C/68
o
F) –
 
accidental exposure only
 
 
ILFORD Dilution 
 
Meter 
setting 
developer  
EI 
EI 
EI
 
Te
mperature (
o
C)
 
Density
 
Te
mperature (
o
F)
 
12/12 100/21 
 
200/24 
and  
and 
below  
above
 
MICROPHEN stock  – 
12
 
ID-11 stock 
4 – –
 
 
 
Note Development times may need adjusting to 
suit individual processing systems and working 
practices. If an established system is producing
 
 
development times until the desired contrast level is 
obtained. Development times in other 
manufacturers’ developers are included for your 
convenience, and are only a general guide. Other 
manufacturers can and do change their product 
specifications from time to time, and the 
development times may change as a result.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
New development time (min)
 
 
CHARACTERISTIC CURVE
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2.0 
 
 
 
1.0 
 
PROCESSING AT DIFFERENT 
TEMPERATURES
 
PAN F Plus film can be processed over a range of 
temperatures. Development times at temperatures 
other than 20°C/68
o
F may be calculated from the 
chart below.
 
 
For example, if 4 minutes at 20°C/68
o
F is 
recommended, the time at 23°C/73
o
F will be 3 
minutes and the time at 16°C/61
o
F will be 6 
minutes.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
New development time (min)
 
1  2 
 3 
 
Relative log exposure
 
 
PAN F Plus rollfilm developed in ILFORD ILFOTEC 
HC (1+31) for 4 minutes at 20°C/68
o
F with 
intermittent agitation. This curve is also 
representative of the 35mm film format.