Ilford 1707768 User Manual
PAN F Plus
Page 4 of 6
DEVELOPMENT TIMES
If PAN F Plus has been inadvertently exposed at
settings below EI 25/15 or above EI 64/19, the
following guide will ensure usable negatives are
obtained. Obviously, the quality of negatives
processed in this way will not be so high as
conventionally processed ones.
Manual processing (min/20
o
C/68
o
F) –
accidental exposure only
ILFORD Dilution
Meter
setting
developer
EI
EI
EI
Te
mperature (
o
C)
Density
Te
mperature (
o
F)
12/12 100/21
200/24
and
and
below
above
MICROPHEN stock –
8
12
ID-11 stock
4 – –
Note Development times may need adjusting to
suit individual processing systems and working
practices. If an established system is producing
development times until the desired contrast level is
obtained. Development times in other
manufacturers’ developers are included for your
convenience, and are only a general guide. Other
manufacturers can and do change their product
specifications from time to time, and the
development times may change as a result.
New development time (min)
CHARACTERISTIC CURVE
2.0
1.0
PROCESSING AT DIFFERENT
TEMPERATURES
PAN F Plus film can be processed over a range of
temperatures. Development times at temperatures
other than 20°C/68
o
F may be calculated from the
chart below.
For example, if 4 minutes at 20°C/68
o
F is
recommended, the time at 23°C/73
o
F will be 3
minutes and the time at 16°C/61
o
F will be 6
minutes.
New development time (min)
1 2
3
4
Relative log exposure
PAN F Plus rollfilm developed in ILFORD ILFOTEC
HC (1+31) for 4 minutes at 20°C/68
o
F with
intermittent agitation. This curve is also
representative of the 35mm film format.