Riello Sentinel Dual SDL 3300 User Manual

Product codes
SDL 3300
Page of 6
90°
90°
1. RELEASE THE DISPLAY PANEL BY    
APPLYING PRESSURE TO THE CATCHES
2. ROTATE THE DISPLAY PANEL COUNTER 
CLOCkwISE AND THEN SECURE IT BACk IN PLACE
3. ROTATE THE UPS BY 90º
4. ATTACH THE RACk SUPPORTS
Simplified installation
•  Can be installed on the floor (tower 
version) or in rack mount cabinets (rack 
version). The display panel can be rotated 
(using the key supplied)
•  Low noise (<40 dBA): can be installed 
in any environment thanks to its high 
frequency switching inverter and PWM 
load-dependent digitally controlled fan.
•  External bypass option for maintenance with 
interruption-free switching (5-6-8-10 kVA 
SDL)
•  Operation guaranteed up to 40°C (the 
components are designed for high 
temperatures and are thus subject to less 
stress at normal temperatures)
•  Two built-in IEC output sockets with thermal 
protection (5-6-8-10 kVA SDL)
•  On the 5-6-8-10 kVA models, it is also 
possible to program two 10 A output 
sockets when the mains power supply fails 
(PowerShare function).
Operating mode selection
Functions can be programmed via software 
or manually via the front display panel.
•  On line
•  Economy Mode: to increase efficiency (up 
to to 98%), allows for the selection of Line 
Interactive technology (VI) to power low 
priority loads from the mains supply
•  Smart Active: the UPS automatically 
decides upon the operating mode (VI or 
VFI) based on the quality of the mains 
power supply
•  Emergency: the UPS can be selected 
to function only when the mains power 
supply fails (emergency only mode).
•  Frequency converter operation (50 or 60 
Hz).
High quality output voltage
•  Even with non-linear loads (IT loads with a 
crest factor of up to 3:1)
•  High short circuit current on bypass
•  High overload capacity: 150% by inverter 
(even with mains failure)
•  Filtered, stabilised and reliable voltage 
(double conversion on-line technology 
(VFI compliant with EN62040-3)), with 
filters for the suppression of atmospheric 
disturbances.
•  Power factor correction: UPS input power 
factor close to 1 and sinusoidal current 
uptake.
High battery reliability
•  Automatic and manual battery test
•  Reduced ripple component (detrimental 
to the batteries) using a low ripple current 
discharge (LCRD) system
•  Batteries are user replaceable without 
switching off equipment and without 
interruption to the load (Hot Swap)
•  Unlimited extendible runtime using 
matching Battery Boxes
•  The batteries do not cut in during mains 
failures of <40 ms (high hold up time) or 
when the input supply is between 84 V to 
276 V.
Emergency function
This configuration ensures the operation 
of those emergency systems that require 
continuous, reliable and long-lasting power 
supply in the event of a mains power failure, 
such as emergency lighting, fire detection/
extinguishing systems and alarms. When the 
mains power supply fails, the inverter begins 
powering the loads with a progressive start-
up (Soft Start) in order to prevent overload.
Battery optimisation
The wide input voltage range and a high 
hold-up time minimise battery usage and 
increase efficiency and battery life; for   
smaller power breaks, energy is drawn from 
a group of appropriately-sized capacitors.
EnergyShare (5-10 kVA versions)
Two 10 A configurable IEC output sockets allow 
for runtime optimisation by programming the 
switching off of low priority loads on mains 
failure; alternatively, emergency loads that are 
normally not powered when mains is present 
can be activated.
Other features
•  Selectable output voltage (220-230-240 V)
•  Auto-restart when mains power is restored 
(programmable via software)
•  Bypass on: when the machine is switched 
off, it automatically goes into bypass and 
battery charge mode
•  Minimum load switch-off
•  Low battery warning
•  Start-up delay
•  Total microprocessor control
•  Automatic bypass without interruption
•  Use of IMS modules (Insulated Metallic 
Substrates)
•  Status, measurements and alarms 
available on standard backlit display
•  UPS digital updating (flash upgradeable)
•  Input protection via resettable thermal 
switch
•  Back-feed protection standard: to prevent 
energy from being fed back to the network
•  Manual switching to bypass.
Advanced communications
•  Advanced multi-platform communications 
for all operating systems and network 
environments: PowerShield
3
 monitoring 
and shutdown software for Windows 
operating systems 8, 7, 2008, Vista, 2003, 
XP, Linux, Mac OS X, Sun Solaris, Linux, 
VMWare ESX and other Unix operating 
systems
•  Plug and play function
•  USB port
•  RS232 serial port
•  Slot for installation of communications 
boards.
2-YEAR wARRANTY