Riello Sentinel Dual SDL 3300 User Manual
Product codes
SDL 3300
90°
90°
1. RELEASE THE DISPLAY PANEL BY
APPLYING PRESSURE TO THE CATCHES
2. ROTATE THE DISPLAY PANEL COUNTER
CLOCkwISE AND THEN SECURE IT BACk IN PLACE
3. ROTATE THE UPS BY 90º
4. ATTACH THE RACk SUPPORTS
Simplified installation
• Can be installed on the floor (tower
version) or in rack mount cabinets (rack
version). The display panel can be rotated
(using the key supplied)
version). The display panel can be rotated
(using the key supplied)
• Low noise (<40 dBA): can be installed
in any environment thanks to its high
frequency switching inverter and PWM
load-dependent digitally controlled fan.
frequency switching inverter and PWM
load-dependent digitally controlled fan.
• External bypass option for maintenance with
interruption-free switching (5-6-8-10 kVA
SDL)
SDL)
• Operation guaranteed up to 40°C (the
components are designed for high
temperatures and are thus subject to less
stress at normal temperatures)
temperatures and are thus subject to less
stress at normal temperatures)
• Two built-in IEC output sockets with thermal
protection (5-6-8-10 kVA SDL)
• On the 5-6-8-10 kVA models, it is also
possible to program two 10 A output
sockets when the mains power supply fails
(PowerShare function).
sockets when the mains power supply fails
(PowerShare function).
Operating mode selection
Functions can be programmed via software
or manually via the front display panel.
• On line
• Economy Mode: to increase efficiency (up
or manually via the front display panel.
• On line
• Economy Mode: to increase efficiency (up
to to 98%), allows for the selection of Line
Interactive technology (VI) to power low
priority loads from the mains supply
Interactive technology (VI) to power low
priority loads from the mains supply
• Smart Active: the UPS automatically
decides upon the operating mode (VI or
VFI) based on the quality of the mains
power supply
VFI) based on the quality of the mains
power supply
• Emergency: the UPS can be selected
to function only when the mains power
supply fails (emergency only mode).
supply fails (emergency only mode).
• Frequency converter operation (50 or 60
Hz).
High quality output voltage
• Even with non-linear loads (IT loads with a
crest factor of up to 3:1)
• High short circuit current on bypass
• High overload capacity: 150% by inverter
• High overload capacity: 150% by inverter
(even with mains failure)
• Filtered, stabilised and reliable voltage
(double conversion on-line technology
(VFI compliant with EN62040-3)), with
filters for the suppression of atmospheric
disturbances.
filters for the suppression of atmospheric
disturbances.
• Power factor correction: UPS input power
factor close to 1 and sinusoidal current
uptake.
uptake.
High battery reliability
• Automatic and manual battery test
• Reduced ripple component (detrimental
• Reduced ripple component (detrimental
to the batteries) using a low ripple current
discharge (LCRD) system
discharge (LCRD) system
• Batteries are user replaceable without
switching off equipment and without
interruption to the load (Hot Swap)
interruption to the load (Hot Swap)
• Unlimited extendible runtime using
matching Battery Boxes
• The batteries do not cut in during mains
failures of <40 ms (high hold up time) or
when the input supply is between 84 V to
276 V.
when the input supply is between 84 V to
276 V.
Emergency function
This configuration ensures the operation
of those emergency systems that require
continuous, reliable and long-lasting power
supply in the event of a mains power failure,
such as emergency lighting, fire detection/
extinguishing systems and alarms. When the
mains power supply fails, the inverter begins
powering the loads with a progressive start-
up (Soft Start) in order to prevent overload.
of those emergency systems that require
continuous, reliable and long-lasting power
supply in the event of a mains power failure,
such as emergency lighting, fire detection/
extinguishing systems and alarms. When the
mains power supply fails, the inverter begins
powering the loads with a progressive start-
up (Soft Start) in order to prevent overload.
Battery optimisation
The wide input voltage range and a high
hold-up time minimise battery usage and
increase efficiency and battery life; for
smaller power breaks, energy is drawn from
a group of appropriately-sized capacitors.
hold-up time minimise battery usage and
increase efficiency and battery life; for
smaller power breaks, energy is drawn from
a group of appropriately-sized capacitors.
EnergyShare (5-10 kVA versions)
Two 10 A configurable IEC output sockets allow
for runtime optimisation by programming the
switching off of low priority loads on mains
failure; alternatively, emergency loads that are
normally not powered when mains is present
can be activated.
for runtime optimisation by programming the
switching off of low priority loads on mains
failure; alternatively, emergency loads that are
normally not powered when mains is present
can be activated.
Other features
• Selectable output voltage (220-230-240 V)
• Auto-restart when mains power is restored
• Auto-restart when mains power is restored
(programmable via software)
• Bypass on: when the machine is switched
off, it automatically goes into bypass and
battery charge mode
battery charge mode
• Minimum load switch-off
• Low battery warning
• Start-up delay
• Total microprocessor control
• Automatic bypass without interruption
• Use of IMS modules (Insulated Metallic
• Low battery warning
• Start-up delay
• Total microprocessor control
• Automatic bypass without interruption
• Use of IMS modules (Insulated Metallic
Substrates)
• Status, measurements and alarms
available on standard backlit display
• UPS digital updating (flash upgradeable)
• Input protection via resettable thermal
• Input protection via resettable thermal
switch
• Back-feed protection standard: to prevent
energy from being fed back to the network
• Manual switching to bypass.
Advanced communications
• Advanced multi-platform communications
for all operating systems and network
environments: PowerShield
environments: PowerShield
3
monitoring
and shutdown software for Windows
operating systems 8, 7, 2008, Vista, 2003,
XP, Linux, Mac OS X, Sun Solaris, Linux,
VMWare ESX and other Unix operating
systems
operating systems 8, 7, 2008, Vista, 2003,
XP, Linux, Mac OS X, Sun Solaris, Linux,
VMWare ESX and other Unix operating
systems
• Plug and play function
• USB port
• RS232 serial port
• Slot for installation of communications
• USB port
• RS232 serial port
• Slot for installation of communications
boards.
2-YEAR wARRANTY