Intel III Xeon 800 MHz 80526KZ800256 User Manual

Product codes
80526KZ800256
Page of 105
ELECTRICAL SPECIFICATIONS 
 
 
 
16 
pull-ups. A resistor of greater than or equal to 10K
Ω may be used to connect the VID signals to the converter input. See 
the VRM 8.3 DC–DC Converter Design Guidelines for further information. 
3.6   
System Bus Unused Pins and Test Pins 
 
Unless otherwise specified, All RESERVED_XXX pins must remain unconnected. Note that pins that are newly marked as 
RESERVED in this document may be tied to a power rail in existing baseboards. See Chapter 7 for a pin listing of the 
processor edge connector for the location of each reserved pin. 
 
NOTE: Pentium® III Xeon™ processor at 700 MHz and 900 MHz pin A11 (RESERVED_A11) may be pulled-down to 
VSS for legacy compatibility. 
 
The TEST_2.5_A62 pin must be connected to 2.5 Volts via a pull-up resistor between 1K and 10K
Ω. 
 
For the Pentium® III Xeon™ processor at 700 MHz and 900 MHz 5V/12V version only, it is recommended that pins that 
were previously specified as TEST_VCC_CORE_XX (now specified TEST_2.5_XX), be connected to the VCC_2.5 supply 
through separate 10K
Ω resistors on the baseboard. However, there will be no damage to cartridges if existing platforms 
provide 2.8 Volts to the pull-up resistors.  All TEST_VTT pins must be connected to the Vtt supply through individual 150
Ω 
resistors. All TEST_VSS pins must be connected individually to the Vss supply through individual 1K
Ω resistors. 
PICCLK must always be driven with a valid clock input. and the PICD[1:0] lines must be pulled-up to 2.5V even when the 
APIC will not be used. A separate pull-up resistor to 2.5V (keep trace short) is required for each PICD line. 
 
For reliable operation, always connect unused inputs to an appropriate signal level. Unused AGTL+ inputs should be left 
as no connects; AGTL+ termination on the processor provides a high level. Unused active low CMOS inputs should be 
connected to 2.5V with a ~10K
Ω resistor. Unused active high CMOS inputs should be connected to ground (VSS). 
Unused outputs may be left unconnected. A resistor must be used when tying bi-directional signals to power or ground. 
When tying any signal to power or ground, a resistor will also allow for system testability. For correct operation when using 
a logic analyzer interface, refer to Chapter 8 for design considerations.  
3.7  System Bus Signal Groups 
 
In order to simplify the following discussion, the system bus signals have been combined into groups by buffer type. All 
system bus outputs should be treated as open drain
 and requires a high-level source provided externally by the 
termination or pull-up resistor.  
 
AGTL+ input signals have differential input buffers, which use 2/3 VTT as a reference level. AGTL+ output signals require 
termination to 1.5V. In this document, the term "AGTL+ Input" refers to the AGTL+ input group as well as the AGTL+ I/O 
group when receiving. Similarly, "AGTL+ Output" refers to the AGTL+ output group as well as the AGTL+ I/O group when 
driving. The AGTL+ buffers employ active negation for one clock cycle after assertion to improve rise times. 
 
The CMOS, Clock, APIC, and TAP inputs can each be driven from ground to 2.5V. The CMOS, APIC, and TAP outputs 
are open drain and should be pulled high to 2.5V. This ensures correct operation for the processor. Timings are specified 
into the load resistance as defined in the AC timing tables. See Chapter 8 for design considerations for debug equipment. 
 
 The SMBus signals should be driven using standard 3.3V CMOS logic levels.