ADC 6624-2-081-00 User Manual

Page of 24
 
LSA-PLUS
®
 Series 
avaNT
i Modules 
and 
Accessories
The LSA-PLUS
®
 Quick Connection Technique
The  Quick  Connection  Technique  is  a  highly  reliable  and  cost  effective  wire  connection  system  for 
modern telecommunications and data networks. It is a comprehensive system built around the widely 
accepted ‘KRONE’ termination module with its range of built-in features. This is complemented with 
an extensive selection of accessories for protection, circuit identification and testing. The LSA-PLUS
® 
system  uses  a  unique  Insulation  Displacement  Contact  (IDC)  technique  which  eliminates  the  need 
to wire-strip, solder or make screw terminations, and dramatically increases productivity. This system  
is supplied for connections in various fields like telecom and structured cabling.
LSA-PLUS
®
 Quick Connection Technique
1. Plastic clamping ribs  
2. Contact slot  
3. Contact tags  
4. Wire  
5. KRONE Insertion Tool. 
6. Torsional forces on the contact 
7. Restoring forces of the contact
 
The ADC LSA-PLUS
®
 contact functions in the same basic manner regardless of the type of module 
in  which  it  is  placed.  Using  the  LSA-PLUS
®
  insertion  tool  (5),  the  plastic  insulated  copper  wire  or 
jumper  (4)  is  inserted  into  the  contact  slot  (2).  The  contact  slot  contains  contact  tags  (3)  set  at  a 
45-degree angle to the wire. Through the action of the tool, the contact tags twist in an axial movement 
and at the same time cut through the wire insulation and push the insulation material to both sides 
of the contact. Through material displacement and the subsequent torsional and restoring forces (6,7) 
of the contact tags, two permanent gas-tight surface areas are formed. This connection prevents any 
movement in the contact area that would undo the connection. For additional protection of the contact 
area, plastic clamping ribs (1) are provided above and below the connection area. These clamping ribs 
firmly grip the wire insulation, preventing any movement of the wire in the contact area. In the same 
termination process, the LSA-PLUS
®
 insertion tool cuts the wire and insulation to the correct length.  
If the wire needs to be re-terminated, the LSA-PLUS
®
 KRONE insertion tool has a swing-out hook, which 
is used to remove the wire from the contact.
7
6