Intel S2600JFQ BBS2600JFQ User Manual
Product codes
BBS2600JFQ
Intel®
Server Board S2600JF TPS
Configuration Jumpers
Revision 1.3
Intel order number G31608-004
115
11. Reconnect the AC cord and power up the server.
Note: Normal BMC functionality is disabled with the Force BMC Update jumper is set to the
enabled position. You should never run the server with the BMC Force Update jumper set in this
position. You should only use this jumper setting when the standard firmware update process
fails. This jumper should remain in the default/disabled position when the server is
running normally.
enabled position. You should never run the server with the BMC Force Update jumper set in this
position. You should only use this jumper setting when the standard firmware update process
fails. This jumper should remain in the default/disabled position when the server is
running normally.
The server board has several 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server board.
recover specific features of the server board.
6.1.2
Force ME Update
(J1E2)
When this 3-pin jumper is set, it manually puts the ME firmware in update mode, which enables
the user to update ME firmware code when necessary.
the user to update ME firmware code when necessary.
Table 55. Force ME Update Jumper
Jumper Position
Mode of
Operation
Note
1-2
Normal
Normal operation
2-3
Update
ME in force update mode
Note: Normal ME functionality is disabled with the Force ME Update jumper is set to the
enabled position. You should never run the server with the ME Force Update jumper set in this
position. You should only use this jumper setting when the standard firmware update process
fails. This jumper should remain in the default/disabled position when the server is
running normally.
enabled position. You should never run the server with the ME Force Update jumper set in this
position. You should only use this jumper setting when the standard firmware update process
fails. This jumper should remain in the default/disabled position when the server is
running normally.
Steps to perform the Force ME Update:
1. Power down and remove the AC power cord.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled
position (covering pins 2 and 3).
4. Close the server chassis.
5. Reconnect the AC cord and power up the server.
6. Perform the ME firmware update procedure as documented in the README.TXT file
that is included in the given ME firmware update package (same package as BIOS).
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position
(covering pins 1 and 2).
10. Close the server chassis.
6.1.3
Password Clear (J1E3)
The user sets this 3-pin jumper to clear the password.