Connector/Header Locations and Pin-out 
Intel®
 
Server Board S2600JF TPS 
 
 
Revision 1.3 
Intel order number G31608-004 
132 
Table 73. SATA Connector 
Pin 
Signal Name 
Description 
GND 
Ground 
SATA_TX_P 
Positive side of transmit differential pair 
SATA_TX_N 
Negative side of transmit differential pair 
GND 
Ground 
SATA_RX_N 
Negative side of receive differential pair 
SATA_RX_P 
Positive side of receive differential pair 
P5V_SATA/GND 
+5V for DOM or Ground for SATA signals 
Note: SATA DOM requires external power cannot be used with SATA-1 port. 
7.4.5 
Hard Drive Activity (Input) LED Header 
Table 74. SATA HDD Activity (Input) LED Header (J6C5) 
Pin 
Description 
LED_HD_ACTIVE_L 
NC 
7.4.6 
Storage Upgrade Key Connector 
The server board provides one SATA/SAS storage upgrade key connector (J6C4) on board. 
The Storage Upgrade Key is a small PCB board that has up to two security EEPROMs that are 
read by the system ME to enable different versions of LSI* RAID 5 software stack and/or 
upgrade from SATA to SAS storage functionality. 
The pin configuration of connector is identical and defined in the following table. 
Table 75. Storage Upgrade Key Connector (J6C4) 
Pin 
Signal Description 
GND 
DYN_SKU_KEY  
GND 
SAS_SATA_RAID_KEY  
7.4.7 
Serial Port Connectors 
The server board provides one internal 9-pin serial A header (J6A2). The following tables define 
the pin-outs. 
Table 76. Internal 9-pin Serial A (COM1) (J6A2) 
Pin 
Signal Name 
Pin 
Signal Name 
SPB_DCD 
SPB_DSR 
SPB_SIN_N 
SPB_RTS 
SPB_SOUT_N 
SPB_CTS 
SPB_DTR 
SPB_RI 
GND