Intel S2600JFQ BBS2600JFQ User Manual
Product codes
BBS2600JFQ
Platform Management Functional Overview
Intel®
Server Board S2600JF TPS
Revision 1.3
Intel order number G31608-004
26
board and “SATA-1” on bridge board, and four 3Gb/s SATA ports routed from the SCU to the
multi-
multi-
drive port connector labeled “SAS/SATA 0-3” (grouped as SCU0).
Note: The multi-
drive port connector labeled “SAS/SATA 4-7” is NOT functional by default and
is only enabled with the addition of an Intel
®
RAID C600 Storage Upgrade Key option supporting
eight SAS/SATA ports.
It supports the Serial ATA Specification, Revision 3.0, and several optional sections of the Serial
ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is required for
some elements).
ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is required for
some elements).
Intel
®
Server Board S2600JF implements six SATA/SAS ports. The implementation is
as follows:
Table 9. Intel
®
Server Board S2600JF SATA/SAS port
Port#
Speed
Connector
0
6Gb/s SATA
Bridge Board Slot
1
6Gb/s SATA
On Server board
SCU0
0
3Gb/s SATA/SAS(non-AHCI)
Bridge Board Slot
1
2
3
There are two embedded software RAID options using the storage ports configured from the
SCU only:
SCU only:
Intel
®
Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW
RAID technology supporting SATA RAID levels 0,1,10, 5
Intel
®
Rapid Storage Technology (RSTe) supporting SATA RAID levels 0,1,5,10
The server board is capable of supporting additional chipset embedded SAS and RAID options
from the SCU controller when configured with one of several available Intel
from the SCU controller when configured with one of several available Intel
®
RAID C600
Storage Upgrade Keys. Upgrade keys install onto a 4-pin connector on the server board labeled
“STOR UPG Key”. The following table identifies available upgrade key options and their
supported features.
“STOR UPG Key”. The following table identifies available upgrade key options and their
supported features.
Table 10. Intel
®
RAID C600 Storage Upgrade Key Options for S2600JF
Intel
®
RAID C600 Upgrade Key
Options (Intel
®
Product Codes)
Key Color
Description
Default
– No option key installed
NA
4 Port SATA with Intel
®
ESRT RAID
0,1,10, and Intel
®
RSTe RAID 0,1,5,10
RKSATA4R5
Black
4 Port SATA with Intel
®
ESRT2 RAID
0,1, 5, 10, and
Intel
®
RSTe RAID 0,1,5,10
RKSAS4
Green
4 Port SAS with Intel
®
ESRT2 RAID 0,1, 10, and
Intel
®
RSTe RAID 0,1,10
RKSAS4R5
Yellow
4 Port SAS with Intel
®
ESRT2 RAID 0,1, 5, 10, and
Intel
®
RSTe RAID 0,1,10
Note: The eight-port Storage Upgrade Key can also implement the RAID function, but only four ports (SCU0) are
user accessible on Intel
user accessible on Intel
®
Server Board S2600JF.