Intel S2600JFQ BBS2600JFQ User Manual

Product codes
BBS2600JFQ
Page of 194
Intel®
 
Server Board S2600JF TPS 
Platform Management Functional Overview 
Revision 1.3 
 
Intel order number G31608-004 
39 
  ACPI state synchronization: The BMC tracks ACPI state changes that are provided 
by the BIOS 
  BMC self-test: The BMC performs initialization and run-time self-tests and makes 
results available to external entities 
See also the Intelligent Platform Management Interface Specification Second Generation v2.0
4.1.2 
Non IPMI Features 
The BMC supports the following non-IPMI features. This list does not preclude support for future 
enhancements or additions. 
  In-circuit BMC firmware update 
  BMC FW reliability enhancements: 
o  Redundant BMC boot blocks to avoid possibility of a corrupted boot block 
resulting in a scenario that prevents a user from updating the BMC. 
o  BMC System Management Health Monitoring 
o  Signed firmware images for increased security 
  Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality. 
  Enable/Disable of System Reset Due CPU Errors 
  Chassis intrusion detection  
  Fan speed control 
  Fan redundancy monitoring and support 
  Hot-swap fan support 
  Power Supply Fan Sensors 
  System Airflow Monitoring 
  Exit Air Temperature Monitoring 
  Acoustic management: Support for multiple fan profiles 
  Ethernet Controller Thermal Monitoring 
  Global Aggregate Temperature Margin Sensor 
  Platform environment control interface (PECI) thermal management support 
  Memory Thermal Management 
  DIMM temperature monitoring: New sensors and improved acoustic management 
using closed-loop fan control algorithm taking into account DIMM 
temperature readings 
  Power supply redundancy monitoring and support 
  Power unit management: Support for power unit sensor. The BMC handles power-
good dropout conditions 
  Intel
®
 Intelligent Power Node Manager support 
  Signal testing support: The BMC provides test commands for setting and getting 
platform signal states. 
  The BMC generates diagnostic beep codes for fault conditions. 
  System GUID storage and retrieval 
  Front panel management: The BMC controls the system status LED and chassis ID 
LED. It supports secure lockout of certain front panel functionality and monitors