4.2  Advanced Configuration and Power Interface (ACPI)  
The server board has support for the following ACPI states: 
Table 15. ACPI Power States 
State 
Supported 
Description 
S0 
Yes 
Working. 
 
The front panel power LED is on (not controlled by the BMC). 
 
The fans spin at the normal speed, as determined by sensor inputs. 
 
Front panel buttons work normally. 
S1 
Yes 
Sleeping. Hardware context is maintained; equates to processor and chipset clocks being 
stopped. 
 
The front panel power LED blinks at a rate of 1 Hz with a 50% duty cycle (not controlled 
by the BMC). 
 
The watchdog timer is stopped. 
 
The power, reset, front panel NMI, and ID buttons are unprotected. 
 
Fan speed control is determined by available SDRs. Fans may be set to a fixed state, or 
basic fan management can be applied. 
The BMC detects that the system has exited the ACPI S1 sleep state when the BIOS SMI 
handler notifies it. 
S2 
No 
Not supported. 
S3 
No 
Supported only on Workstation platforms. See appropriate Platform Specific Information for 
more information. 
S4 
No 
Not supported. 
S5 
Yes 
Soft off 
 
The front panel buttons are not locked. 
 
The fans are stopped. 
 
The power-up process goes through the normal boot process. 
 
The power, reset, front panel NMI, and ID buttons are unlocked. 
 
4.3  Platform Management SMBus* and I
2
C Implementation 
SMBus*/ I
2
C interconnections are a fundamental interface for various manageability 
components. There are three buses that are used in a multi-master fashion.  
 
Primary IPMB. An IPMB header is provided on the baseboard to support connectivity 
with third-party management PCIe cards. This bus operates as 100 kHz bus. 
 
Secondary IPMB. This is the SMLink0 bus that connects the BMC with the ME in the 
SSB. This bus is considered a secondary IPMB. The ME and BMC communicate over 
this bus using IPMB protocol messages. Any devices on the bus must be 400 kHz 
bus tolerant. 
 
PMBus*. This is the SMLink1 bus that both the ME and BMC use to communicate with 
the power supplies. This bus operates as 100 kHz bus. 
For all multi-master buses, the master that initiates a transaction is responsible for any bus 
recovery sequence if the bus hangs. 