Platform Management Functional Overview 
Intel®
 
Server Board S2600JF TPS 
 
 
Revision 1.3 
Intel order number G31608-004 
50 
4.9  Field Replaceable Unit (FRU) Inventory Device 
The BMC implements the interface for logical FRU inventory devices as specified in the 
Intelligent Platform Management Interface Specification, Version 2.0. This functionality provides 
commands used for accessing and managing the FRU inventory informationThese commands 
can be delivered through all interfaces. 
The BMC provides FRU device command access to its own FRU device and to the FRU 
devices throughout the server. The FRU device ID mapping is defined in the Platform Specific 
Information. The BMC controls the mapping of the FRU device ID to the physical device. 
4.10  Diagnostics and Beep Code Generation  
The BMC may generate beep codes upon detection of failure conditions. Beep codes are 
sounded each time the problem is discovered (for example, on each power-up attempt), but are 
not sounded continuously. Common supported codes are listed in Table 19. 
Additional platform-specific beep codes can be found in the appropriate Platform Specific 
Information. Each digit in the code is represented by a sequence of beeps whose count is equal 
to the digit. 
Table 19. BMC Beep Codes 
Code 
Reason for Beep 
Associated Sensors 
Supported 
1-5-2-1 
No CPUs installed or first CPU socket is 
empty.  
CPU Missing Sensor  
Yes 
1-5-2-4 
MSID Mismatch. 
MSID Mismatch Sensor. 
Yes 
1-5-4-2 
Power fault: DC power is unexpectedly 
lost (power good dropout). 
Power unit 
– power unit failure 
offset. 
Yes 
1-5-4-4 
Power control fault (power good assertion 
timeout). 
Power unit 
– soft power control 
failure offset. 
Yes 
1-5-1-2 
VR Watchdog Timer sensor assertion 
VR Watchdog Timer  
 
Yes 
1-5-1-4 
The system does not power on or 
unexpectedly powers off and a power 
supply unit (PSU) is present that is an 
incompatible model with one or more 
other PSUs in the system 
PSU status 
Yes 
 
4.11  Diagnostics Interrupt (NMI)  
The BMC generates an NMI pulse under certain conditions. The BMC-generated NMI pulse 
duration is at least 30ms. Once an NMI has been generated by the BMC, the BMC does not 
generate another NMI until the system has been reset or powered down. 
The following actions cause the BMC to generate an NMI pulse: 
a.  Receiving a Chassis Control command to pulse the diagnostic interrupt. This command 
does not cause an event to be logged in the SEL. 
b.  Detecting that the front panel diagnostic interrupt button has been pressed