Eaton Powerware 9155-10-SL-6-32x7Ah 1022541 User Manual
Product codes
1022541
Premium power performance
Double-conversion design for highest power protection
Unlike some other commercially available UPS technologies,
the double-conversion design used in the 9155/9355 completely
isolates output power from input power anomalies and delivers
100-percent conditioned, perfect sine wave output, regulating
both voltage and frequency. Even when presented with the most
severe power disturbances, power output remains stable.
the double-conversion design used in the 9155/9355 completely
isolates output power from input power anomalies and delivers
100-percent conditioned, perfect sine wave output, regulating
both voltage and frequency. Even when presented with the most
severe power disturbances, power output remains stable.
The 9155/9355 continually monitors incoming electrical power and
removes all power irregularities that are inherent in commercial
utility power. During power outages and other interruptions, inter-
nal batteries provide emergency power to safeguard operation.
removes all power irregularities that are inherent in commercial
utility power. During power outages and other interruptions, inter-
nal batteries provide emergency power to safeguard operation.
With the 9155/9355 UPS, data centre and facility managers can
rest assured that their systems and equipment are fully protected
from the effects of mains disturbances.
rest assured that their systems and equipment are fully protected
from the effects of mains disturbances.
Self-diagnosis
The 9155/9355 constantly monitors its own operation – including
voltage, temperature and function of internal components – and
sends an alarm or takes action if it detects a potential problem.
The 9155/9355 constantly monitors its own operation – including
voltage, temperature and function of internal components – and
sends an alarm or takes action if it detects a potential problem.
Efficiency and cost savings
The 9155/9355 delivers a robust combination of low input current
distortion and high power factor for maximum efficiency. Operating
at greater than 90 percent efficiency across all load ranges, the
9155/9355 helps to reduce utility costs, extend battery runtimes
and produce cooler operating conditions.
distortion and high power factor for maximum efficiency. Operating
at greater than 90 percent efficiency across all load ranges, the
9155/9355 helps to reduce utility costs, extend battery runtimes
and produce cooler operating conditions.
In addition, Eaton´s use of sustainable materials and highly effi-
cient manufacturing technology results in savings in carbon foot
print compared to competitive UPS products.
cient manufacturing technology results in savings in carbon foot
print compared to competitive UPS products.
The 9155/9355 UPS provides industry-leading power density and a
10-40 percent footprint reduction versus comparable UPS solutions.
10-40 percent footprint reduction versus comparable UPS solutions.
All standard 9155/9355 configurations incorporate internal bat-
teries to provide significantly more runtime and offer 13 percent
more capacity at equivalent VA ratings. Extended runtime allows
the 9155/9355 to power this extra capacity for nearly four times
longer without requiring additional hardware, eliminating the need
for costly and space-consuming external battery cabinets.
teries to provide significantly more runtime and offer 13 percent
more capacity at equivalent VA ratings. Extended runtime allows
the 9155/9355 to power this extra capacity for nearly four times
longer without requiring additional hardware, eliminating the need
for costly and space-consuming external battery cabinets.
Standard 10 kVA and 20 kVA capacity models can also be upgrad-
ed to 15 kVA and 30 kVA respectively, providing 50 percent more
power with no additional hardware and no increase in footprint.
The small footprint of the 9155/9355 enables easy space planning
for data centres and saves valuable floorspace.
ed to 15 kVA and 30 kVA respectively, providing 50 percent more
power with no additional hardware and no increase in footprint.
The small footprint of the 9155/9355 enables easy space planning
for data centres and saves valuable floorspace.
Self-correction
If it senses a problem, the 9155/9355 instantly transfers the power
path to a bypass source with zero interruption in power. When the
alarm condition passes, the 9155/9355 automatically reverts from
bypass to normal power.
If it senses a problem, the 9155/9355 instantly transfers the power
path to a bypass source with zero interruption in power. When the
alarm condition passes, the 9155/9355 automatically reverts from
bypass to normal power.
The 9155/9355 features a graphical LCD that provides useful infor-
mation such as load status, events, measurements and settings.
mation such as load status, events, measurements and settings.
The 9155/9355 UPS provides a 10-40 percent footprint reduction versus comparable UPS solutions
Maintenance bypass
Static bypass (switch)
AC Source
Rectifier/Charger
Inverter
IT Loads
DC Link
Battery
Normal power flow
Stored energy power flow
Recharge energy flow
Stored energy power flow
Recharge energy flow
20-40 kVA UPS
8-15 kVA UPS
www.eaton.com/powerquality 3