Electrostatic Discharge (ESD) 
The Industrial Grade UFD has been tested for immunity from ESD under the conditions described in Table 
10. 
 
Table 10: Electrostatic Discharge for UFD  
ESD Type 
ESD Rated Enclosure  
(Maximum Discharge) 
Contact 
8KV 
Air 
15KV 
4.5 
Mean Time Between Failure (MTBF) 
STEC estimates Mean Time Between Failure (MTBF), using a prediction methodology based on reliability 
data for the individual components in the USB Flash Drive. Table 11 summarizes the prediction results for 
the USB Flash Disk Drive, based on the following two methodologies: 
 
Telcordia Special Report SR-332, Reliability Prediction Procedure for Electronic Equipment. 
 
MIL-HNBK-217 
The analysis was performed using Relex Software.  
Table 11: USB Flash Drive MTBF  
Product 
Condition 
MTBF (hours) 
SLUFD4GU2TU 
Telcordia SR-332, GB, 25°C 
MIL-HNBK-217 
>4,000,000  
SLUFD8GU2TU 
Telcordia SR-332, GB, 25°C 
MIL-HNBK-217 
>4,000,000 
4.6 
Standards Compliance 
USB Flash Drive complies with the following standards: 
 
CE - EN 55022/55024 
 
FCC - Class B for Information Technology 
 
UL 60950 
 
RoHS-6 
 
USB 2.0 
– Mass Storage Class