Intel S2600JF BBS2600JF User Manual

Product codes
BBS2600JF
Page of 194
Intel®
 
Server Board S2600JF TPS  
Connector/Header Locations and Pin-out 
Revision 1.3 
 
 
Intel order number G31608-004 
119 
7.  Connector/Header Locations and Pin-out 
7.1  Power Connectors 
To facilitate customers who want to cable to this board from a power supply, the power 
connector is implemented through two 6pin pin Minifit Jr* connectors, that can be used to deliver 
12amps per pin or 60+Amps total.
 
Note that no over-voltage protective circuits will exist on 
the board. 
Table 59. Main Power Supply Connector 6-pin 2x3 Connector (J4K1 and J3K1) 
Pin 
Signal Name 
Pin 
Signal Name 
GND 
+12V 
GND 
+12V 
GND 
+12V 
7.2  System Management Headers 
7.2.1 
Intel
® 
Remote Management Module 4 (Intel
® 
RMM4 Lite) Connector 
A 7-pin Intel
® 
RMM4 Lite connector (J1A2) is included on the server board to support the 
optional Intel
®
 Remote Management Module 4. There is no support for third-party management 
cards on this server board. 
Note: This connector is not compatible with the Intel
®
 
Remote Management Module 3 
(Intel
®
 
RMM3). 
Table 60. Intel
®
 RMM4 Lite Connector Pin-out (J1A2) 
Pin 
Signal Description 
Pin 
Signal Description 
DI 
VCC 
CLK 
KEY 
GND 
DO 
GND 
CS_N 
7.2.2 
IPMB Header 
Table 61. IPMB Header 4-pin (J2D2) 
Pin 
Signal Name 
Description 
SMB_IPMB_5VSB_DAT 
BMC IPMB 5V standby data line 
GND 
Ground 
SMB_IPMB_5VSB_CLK 
BMC IPMB 5V standby clock line 
P5V_STBY 
+5V standby power 
7.3  Bridge Board Connector 
The bridge board delivers SATA/SAS signals, Disk back plane management signals, BMC 
SMBus*es as well as SSI-Compliant front panel and miscellaneous Node specific signals.
 
The 
fifth SAS connection was added to support a Raid 5 + hot spare configuration.
 
This drives the 
addition of a second set of SGPIO pins.