Intel S2600JF BBS2600JF User Manual
![Intel](https://files.manualsbrain.com/attachments/5a71b1e7f60391972dadeef20435931cbf4621a5/common/fit/150/50/86c99b5f14aeb2708e9a9e1b5305af4ccf882c1af0155dad25413c2ed84e/brand_logo.png)
Product codes
BBS2600JF
Intel®
Server Board S2600JF TPS
Connector/Header Locations and Pin-out
Revision 1.3
Intel order number G31608-004
119
7. Connector/Header Locations and Pin-out
7.1 Power Connectors
To facilitate customers who want to cable to this board from a power supply, the power
connector is implemented through two 6pin pin Minifit Jr* connectors, that can be used to deliver
12amps per pin or 60+Amps total.
connector is implemented through two 6pin pin Minifit Jr* connectors, that can be used to deliver
12amps per pin or 60+Amps total.
Note that no over-voltage protective circuits will exist on
the board.
Table 59. Main Power Supply Connector 6-pin 2x3 Connector (J4K1 and J3K1)
Pin
Signal Name
Pin
Signal Name
1
GND
4
+12V
2
GND
5
+12V
3
GND
6
+12V
7.2 System Management Headers
7.2.1
Intel
®
Remote Management Module 4 (Intel
®
RMM4 Lite) Connector
A 7-pin Intel
®
RMM4 Lite connector (J1A2) is included on the server board to support the
optional Intel
®
Remote Management Module 4. There is no support for third-party management
cards on this server board.
Note: This connector is not compatible with the Intel
®
Remote Management Module 3
(Intel
®
RMM3).
Table 60. Intel
®
RMM4 Lite Connector Pin-out (J1A2)
Pin
Signal Description
Pin
Signal Description
1
DI
2
VCC
3
CLK
4
KEY
5
GND
6
DO
7
GND
8
CS_N
7.2.2
IPMB Header
Table 61. IPMB Header 4-pin (J2D2)
Pin
Signal Name
Description
1
SMB_IPMB_5VSB_DAT
BMC IPMB 5V standby data line
2
GND
Ground
3
SMB_IPMB_5VSB_CLK
BMC IPMB 5V standby clock line
4
P5V_STBY
+5V standby power
7.3 Bridge Board Connector
The bridge board delivers SATA/SAS signals, Disk back plane management signals, BMC
SMBus*es as well as SSI-Compliant front panel and miscellaneous Node specific signals.
SMBus*es as well as SSI-Compliant front panel and miscellaneous Node specific signals.
The
fifth SAS connection was added to support a Raid 5 + hot spare configuration.
This drives the
addition of a second set of SGPIO pins.