Intel S2600JF BBS2600JF User Manual

Product codes
BBS2600JF
Page of 194
Product Architecture Overview 
Intel®
 
Server Board S2600JF TPS 
 
 
Revision 1.3 
Intel order number G31608-004 
12 
Table 3. Mixed Processor Configurations  
Error 
Severity  
System Action 
Processor family not 
identical 
Fatal 
The BIOS detects the error condition and responds as follows: 
  Logs the error into the system event log (SEL). 
  Alerts the Integrated BMC of the configuration error with an IPMI 
command. 
  Does not disable the processor. 
 
Displays “0194: Processor family mismatch detected” message in 
the error manager. 
  Halts the system. 
Processor cache not 
identical 
Fatal 
The BIOS detects the error condition and responds as follows: 
  Logs the error into the SEL. 
  Alerts the Integrated BMC of the configuration error with an IPMI 
command. 
  Does not disable the processor. 
 
Displays “0192: Cache size mismatch detected” message in the 
error manager. 
  Halts the system. 
Processor frequency (speed) 
not identical 
Major 
The BIOS detects the error condition and responds as follows: 
  Adjusts all processor frequencies to lowest common 
denominator. 
  Continues to boot the system successfully. 
 
If the frequencies for all processors cannot be adjusted to be the 
same, then the BIOS: 
  Logs the error into the SEL. 
 
Displays “0197: Processor speeds mismatched” message in the 
error manager. 
  Halts the system. 
Processor microcode 
missing 
Fatal 
The BIOS detects the error condition and responds as follows: 
  Logs the error into the SEL. 
  Alerts the Integrated BMC of the configuration error with an IPMI 
command. 
  Does not disable processor. 
 
Displays “816x: Processor 0x unable to apply microcode update” 
message in the error manager. 
  Pauses the system for user intervention. 
Processor Intel
®
 QuickPath 
Interconnect speeds not 
identical 
Halt 
The BIOS detects the error condition and responds as follows: 
  Logs the error into the system event log (SEL). 
  Alerts the Integrated BMC of the configuration error with an IPMI 
command. 
  Does not disable the processor. 
 
Displays “0195: Processor Front Side Bus speed mismatch 
detected” message in the error manager. 
  Halts the system. 
When a single processor is installed, no terminator is required in the second processor socket.