61 
 
Figure 20. Management Engine Distribution Model 
4.14.3 
ME System Management Bus (SMBus*) Interface 
  The ME uses the SMLink0 on the SSB in multi-master mode as a dedicated bus for 
communication with the BMC using the IPMB protocol. The EPSD BMC FW considers 
this a secondary IPMB bus and runs at 400 kHz. 
  The ME uses the SMLink1 on the SSB in multi-master mode bus for communication with 
PMBus* devices in the power supplies for support of various NM-related features. This 
bus is shared with the BMC, which polls these PMBus* power supplies for sensor 
monitoring purposes (for example, power supply status, input power, and so on.). This 
bus runs at 100 KHz. 
 
The Management Engine has access to the “Host SMBus*”. 
4.14.4 
BMC - Management Engine Interaction 
Management Engine-Integrated BMC interactions include the following: 
  Integrated BMC stores sensor data records for ME-owned sensors. 
  Integrated BMC participates in ME firmware update. 
  Integrated BMC initializes ME-owned sensors based on SDRs. 
  Integrated BMC receives platform event messages sent by the ME. 