Finisar FTLX1612M3BTL User Manual

Page of 12
FTLX1612M3BTL I-Temp 40km XFP Product Specification – November 2009 
F i n i s a r
 
 
 
© Finisar Corporation 30-November-2009    
Rev B2 
Page 2 
I. 
Pin Descriptions  
 
Pin Logic 
Symbol 
Name/Description 
Ref. 
1  
GND 
Module 
Ground 
 
VEE5 
Optional –5.2 Power Supply – Not Required 
 
LVTTL-I 
Mod-Desel 
Module De-select; When held low allows the module to 
respond to 2-wire serial interface commands 
 
4 LVTTL-O 
 
Interrupt 
Interrupt (bar); Indicates presence of an important condition 
which can be read over the serial 2-wire interface 
LVTTL-I 
TX_DIS 
Transmitter Disable; Transmitter laser source turned off 
 
 
VCC5 
+5 Power Supply 
 
7  
GND 
Module 
Ground 
 
VCC3 
+3.3V Power Supply 
 
 
VCC3 
+3.3V Power Supply 
 
10 
LVTTL-I 
SCL 
Serial 2-wire interface clock 
11 LVTTL-
I/O 
SDA 
Serial 2-wire interface data line 
12 
LVTTL-O 
Mod_Abs 
Module Absent; Indicates module is not present. Grounded 
in the module. 
13 
LVTTL-O 
Mod_NR 
Module Not Ready; Finisar defines it as a logical OR 
between RX_LOS and Loss of Lock in TX/RX. 
14 
LVTTL-O 
RX_LOS 
Receiver Loss of Signal indicator 
15  
GND 
Module 
Ground 
16  
GND 
Module 
Ground 
17 
CML-O 
RD- 
Receiver inverted data output 
 
18 
CML-O 
RD+ 
Receiver non-inverted data output 
 
19  
GND 
Module 
Ground 
20 
 
VCC2 
+1.8V Power Supply – Not Required 
 
Power Down; When high, places the module in the low 
power stand-by mode and on the falling edge of P_Down 
initiates a module reset 
 
21 LVTTL-I 
P_Down/RST 
Reset; The falling edge initiates a complete reset of the 
module including the 2-wire serial interface, equivalent to a 
power cycle. 
 
22 
 
VCC2 
+1.8V Power Supply – Not Required 
 
23  
GND 
Module 
Ground 
24 
PECL-I 
RefCLK+ 
Reference Clock non-inverted input, AC coupled on the 
host board – Not required 
 
25 
PECL-I 
RefCLK- 
Reference Clock inverted input, AC coupled on the host 
board – Not required 
 
26  
GND 
Module 
Ground 
27  
GND 
Module 
Ground 
28 
CML-I 
TD- 
Transmitter inverted data input 
 
29 
CML-I 
TD+ 
Transmitter non-inverted data input 
 
30  
GND 
Module 
Ground 
 
Notes: 
1.  Module circuit ground is isolated from module chassis ground within the module. 
2.  Open collector; should be pulled up with 4.7k – 10kohms on host board to a voltage between 3.15V 
and 3.6V.