Adtran SFP 3.125Gbps 1552.52nm DWDM 1442890G2 Leaflet

Product codes
1442890G2
Page of 2
NOTE
The Gigabit port(s) are optical and therefore are not 
classified as any type of port as defined in Appendix B of 
GR-1089-CORE, Issue 4.
The SFP is designed to meet the following environmental 
classes:
ETSI EN 300 019-1-1 “Classification of environmental 
conditions; Storage,” Class 1.2
ETSI EN 300 019-1-2 “Classification of environmental 
conditions; Transportation,” Class 2.3
ETSI EN 300 019-1-3 “Classification of environmental 
conditions; Stationary use at weather-protected 
locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class 3.3
The 3.125 Gagabit Ethernet 1552.52 nm DWDM Small 
Form-Factor Pluggable meets EU RoHS Directive 2002/
95/EC and/or applicable exemptions. Refer to 
 for further information on RoHS/
WEEE. 
NOTE
T h i s   S F P   i s   c o m p l i a n t   w i t h   S F F - 8 4 7 2   “ D i g i t a l  
D i a g n o s t i c s   M o n i t o r i n g   I n t e r f a c e   f o r   O p t i c a l  
Transceivers,” Revision 9.3. 
This SFP is compliant with the Small Form-Factor 
Pluggable (SFP) Multi-Source Agreement (MSA).
This device complies with Part 15 of the FCC rules. 
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, 
including interference that may cause undesired 
operation.
Changes or modifications not expressly approved by 
ADTRAN could void the user's authority to operate this 
equipment.
♦  
Per GR-1089-CORE, the ADTRAN system in which the 
SFP is being deployed is designed and intended for 
installation as part of a Common Bonding Network 
(CBN). The ADTRAN system in which the SFP is being 
deployed is not designed nor intended for installation 
as part of an Isolated Bonding Network (IBN).
♦  
Per GR-1089-CORE Section 9, the SFP does not have 
an internal DC connection between battery return and 
frame ground. The SFP can be installed in a DC-I 
(isolated) or DC-C (common) installation. For 
installations where other cards or the host system 
have internal connections between battery return and 
frame ground, the system would be intended for 
deployment only in a DC-C installation.
The ADTRAN system chassis frame ground terminal 
must be connected to a reliable earth ground to ensure 
that the metal enclosure of the SFP is properly grounded 
via the backplane connector.
The SFP is a Class 1 Laser Product and complies with the 
Laser Safety requirements of FDA 21CFR 1040.10 and 
1040.11, and EN60825-1 and -2. The SFP is NRTL listed 
and CB Certified to all applicable American and 
European safety standards. 
For continued compliance with the above laser safety 
standards, only approved Class 1 modules from our 
approved vendor list, located on the ADTRAN website, 
should be installed in ADTRAN products.
Warranty
: ADTRAN will replace or repair this product within the warranty period if it does not meet its 
published specifications or fails while in service. Warranty information can be found online at 
www.adtran.com/warranty
.
© 2009 ADTRAN, Inc. All Rights Reserved.
*61442890G2-22A*
C A U T I O N ! 
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CLEI: BVL3AF0D_ _
Product P/N: 1442890G2
Issue Date: 0906
Document P/N: 61442890G2-22A
PRICING AND AVAILABILITY
800.827.0807
TECHNICAL SUPPORT
800.726.8663
RETURN FOR REPAIR
256.963.8722
Small Form-Factor Pluggable
3.125 Gigabit Ethernet 1552.52  nm DWDM