iStarUSA IS-600P User Manual

Page of 10
7
4.1 Over Power Protection 
The OPP function shall work at 130%~270% of rating of output power, then all outputs shut down in a 
latch off mode. The latch shall be cleared by toggling the PSON# signal or by cycling the AC power. 
The power supply shall not be damaged from repeated power cycling in this condition. If only one 
module works inside the power supply, the OPP is at 110%~170% of rating of power supply. 
4.2 Over Voltage Protection 
Each hot swap module has respective OVP circuit. Once any power supply module shut down in a latch off 
mode while the output voltage exceeds the over voltage limit shown in Table 7, the other modules should 
deliver the sufficient power to the device continually.   
Voltage  
Minimum 
Maximum  
Shutdown 
Mode 
+5V +5.7V 
+6.5V 
Latch 
Off 
+3.3V +3.9V 
+4.5V 
Latch 
Off 
+12V +13.3V 
+14.5V 
Latch 
Off 
5VSB +5.7V 
+6.5V 
Auto 
recovery 
Table 7 –Over Voltage protection 
4.3 Over Current Protection 
The power supply should contain the OCP function on each hot swap module. The power supply should be 
shut down in a latch off mode while the respective output current exceeds the limit as shown in Table 8. 
When the latch has been cleared by toggling the PSON# single or cycling the AC input power. The power 
supply module should not be damaged in this condition.   
Voltage  
Minimum 
Maximum  
Shutdown 
Mode 
+5V 110% 160% 
Latch 
Off 
+3.3V 110% 160% 
Latch 
Off 
+12V 110% 160% 
Latch 
Off 
Table 8 –Over Current protection 
4.4 Short Circuit Protection   
The power supply shall shut down in a latch off mode when the output voltage is short circuit. 
5. Environmental Requirements 
5.1 Temperature 
Operating Temperature Range: 
0
°C ~ 50°C (32°F~ 104°F)
Non-Operating Temperature Range: -40°C ~ 70°C (-40°F~ 158°F)
5.2 Humidity 
Operating Humidity Range: 
20% ~ 90%RH non-condensing 
Non-Operating Humidity Range: 
5% ~ 95%RH non-condensing