iStarUSA IS-1800RH1UP User Manual

Page of 10
5
PSON# controlling the On/Off of the power supply.     
Item Description 
MIN 
MAX 
 
Units 
T
v
out_rise
 
 Output voltage rise time from each main output.(+5Vsb < 
70mS)
5
70 mS 
T
vout_on
 
 All main output must be within regulation of each other 
within this time. 
 50 
mS 
T
vout_off
 
All main output must leave regulation within this time 
 
400 
mS 
Table 4 – Output Voltage Timing 
          Vout 
                      V1     
10% Vout
                               
                      V2 
                      V3 
                      V4 
                                                             
T
vout_on
                                                   
T
vout_off
                               
                               
T
v
out_rise
Figure 1 : Output Voltage Timing 
Table 5 – Turn On/Off Timing 
Item Description 
MIN 
MAX 
 
Units 
T
sb_on-delay
   Delay from AC being applied to +5VSB being within 
regulation. 
 1500 
mS 
T
ac_on-delay
 
  Delay from AC being applied to all output voltages being   
within regulation. 
 2500 
mS 
T
vout_holdup
All main output voltage stay within regulation after loss of 
AC
18  mS 
T
pwok_holdup
    Delay from loss of AC deassertion of PWOK. 
17 
 
mS 
T
pson_on_delay
 
 Delay from PSON# active to output voltage within 
regulation limits. 
5 400 
mS 
T
pson_pwok
 
  Delay from PSON# deactive to PWOK being deasserted. 
 
50 
mS 
T
pwok_on
 
  Delay from output voltage within regulation limits to PWOK 
asserted at turn on. 
100 500 mS 
T
pwok_off
 
 Delay from PWOK deasserted to output voltages (+5V, 
+3.3V, +12V) dropping out of regulation limits.   
1  
mS 
T
pwok_low
 
  Duration of PWOK being in the deasserted state during an 
off/on cycle using AC or the PSON# signal. . 
100  mS 
T
sb_vout
 
 Delay from +5VSB being in regulation to O/Ps being in 
regulation at AC turn on. 
50 1000 mS