6. Agency Requirements 
6.1 Safety Certification. 
Product Safety:   
UL 60950-1 2000Edition, IEC60950-1, 3
rd
 Edition
EU Low Voltage Directive (73/23/EEC) (CB) 
TÜV
RFI Emission: 
FCC Part15 ( Radiated & Conducted Emissions )
CISPR 22,3
rd
 Edition / 
EN55022: 1998 + A1: 2000
)
PFC Harmonic: 
EN61000-3-2:2000
Flicker: 
EN61000-3-3: 1995 + A1: 2002
Immunity against: 
-Electrostatic discharge: 
-Radiated field strength: 
-Fast transients: 
-Surge voltage: 
-RF Conducted 
-Voltage Dips and Interruptions 
EN55024: 1998 + A1: 2001 and A2: 2003 
-IEC 61000-4-2 
-IEC 61000-4-3 
-IEC 61000-4-4 
-IEC 61000-4-5 
-IEC 61000-4-6 
-IEC 61000-4-11   
Table 8 –
Safety Certification
6.2 AC Input Leakage Current 
Input leakage current from line to ground will be less than 3.5mA rms. Measurement will be made at 
240 VAC and 60Hz. 
7. Redundant Power Supply Function 
7.1 Redundancy 
The redundant power supply is N+1=1800W(600W N+1)
        function power supply, each one module 
is redundancy when any one module was failed. To be redundant each item must be in the Hot swap 
power supply module. 
7.2 Hot Swap Requirements 
The redundant power supply modules shall be hot swappable. Hot swapping a power supply is the 
process of inserting and extracting a power supply from an operating. During this process the 
output voltage shall remain within the limits specified in Table 7 with the capacitive load specified 
Table 9. The Sub-system shall not exceed the maximum inrush current as specified in section 2.2. 
The power supply can be hot swapped by the following methods:     
˗ġ AC connecting separately to each module. Up to two power supplies may be on a single AC power 
source. 
Extraction: The AC power will be disconnected from the power supply first and then the power 
supply is extracted from the sub-system. This could occur in standby mode or powered on mode. 
Insertion: The module is inserted into the cage and then AC power will be connected to the power 
supply module.