Samsung 320MX-3 LH32HBPLBCEN User Manual

Product codes
LH32HBPLBCEN
Page of 147
No.
command type
command
Value range
1
Power control
0x11
0~1
2
Volume control
0x12
0~100
3
Input source control
0x14
-
4
Screen Mode control
0x18
-
5
Screen Size control
0x19
0~255
6
PIP on/off control
0x3C
0~1
7
Auto adjustment control
0x3D
0
8
Video wall Mode control
0x5C
0~1
9
Safety Lock
0x5D
0~1
- ID should show hexadecimal value of assigned ID, but ID 0 should be 0xFF.
- Every communication will be made in hexadecimals and Checksum is the sum of all
remainings. If it exceeds two digits,for example, it is 11+FF+01+01=112, discard the
number in the first digit like below.
example)PowerOn&ID=0
Header
command
ID
DATA
Length
DATA 1
CheckSum
0xAA
0x11
1
Power
Header
command
ID
DATA
Length
DATA 1
12
0xAA
0x11
1
1
If you want to control every mechanism connected with Serial Cable regardless of its ID,
set ID part to "0xFE" and send commands. At the time, each product will follow commands
but it will not respond with ACK.
Power Control
Function
Get Power ON/OFF Status
Header
command
ID
DATA Length
CheckSum
0xAA
0x11
0
Set Power ON/OFF
Header
command
ID
DATA
Length
DATA
CheckSum
0xAA
0x11
1
Power
1 : Power ON
Introduction
Personal Computer turns TV or Monitor power ON/OFF.
Power : Power code to be set on TV or Monitor