Intel G640T BX80623G640T Data Sheet

Product codes
BX80623G640T
Page of 104
Datasheet
85
Thermal Specifications and Design Considerations
5.4.2
PECI Specifications
5.4.2.1
PECI Device Address
The PECI device address for the socket is 30h. For more information on PECI domains, 
refer to the Platform Environment Control Interface Specification
5.4.2.2
PECI Command Support
PECI command support is covered in detail in the Platform Environment Control 
Interface Specification. Refer to this document for details on supported PECI command 
function and codes.
5.4.2.3
PECI Fault Handling Requirements
PECI is largely a fault tolerant interface, including noise immunity and error checking 
improvements over other comparable industry standard interfaces. The PECI client is 
as reliable as the device that it is embedded in, and thus given operating conditions 
that fall under the specification, the PECI will always respond to requests and the 
protocol itself can be relied upon to detect any transmission failures. There are, 
however, certain scenarios where the PECI is know to be unresponsive.
Prior to a power on RESET# and during RESET# assertion, PECI is not ensured to 
provide reliable thermal data. System designs should implement a default power-on 
condition that ensures proper processor operation during the time frame when reliable 
data is not available via PECI. 
To protect platforms from potential operational or safety issues due to an abnormal 
condition on PECI, the Host controller should take action to protect the system from 
possible damaging states. It is recommended that the PECI host controller take 
appropriate action to protect the client processor device if valid temperature readings 
have not been obtained in response to three consecutive gettemp()s or for a one 
second time interval. The host controller may also implement an alert to software in the 
event of a critical or continuous fault condition. 
5.4.2.4
PECI GetTemp0() Error Code Support
The error codes supported for the processor GetTemp() command are listed in 
.
§ §
Table 32.
GetTemp0() Error Codes
Error Code
Description
8000h
General sensor error
8002h
Sensor is operational, but has detected a temperature below its operational 
range (underflow).