Fujitsu TX300 S7 VFY:T3007SF020CH Data Sheet

Product codes
VFY:T3007SF020CH
Page of 9
Data Sheet
 Fujitsu PRIMERGY TX300 S7 Server 
Page 6 / 9
www.fujitsu.com/fts
Operating Systems and Virtualization Software
Operating system notes
Support of other Linux derivatives on demand
Server Management
Standard
ServerView Remote Management (iRMC)
Option
ServerView Suite - Deploy 
 
SV Deployment Manager (full version)
ServerView Suite - Maintain
 
iRMC Advanced Pack incl. Advanced Video Redirection (AVR) and Remote Storage
ServerView Suite - Dynamize 
 
SV Virtual-IO Manager (VIOM)
 
SV Resource Orchestrator Virtual Edition (ROR VE)
 
SV Resource Orchestrator Cloud Edition (ROR CE)
ServerView Suite - Integrate
 
SV Integration pack for Fujitsu ManageNow® solution
Server Management notes
Regarding Operating System dependencies for ServerView Suite Software Products see dedicated Product Data sheets.
Dimensions / Weight
Floor-stand (W x D x H)
177 x 777 x 456 mm
Weight
up to 35 kg
Weight notes
Actual weight may vary depending on configuration
Rack integration kit
Rack integration kit as option
Environmental
Operating ambient temperature
10 - 35°C
Operating relative humidity
10 - 85 % (non condensing)
Operating environment
FTS 04230 – Guideline for Data Center (installation locations)
Operating environment Link
http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Noise emission
Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm)
Low noise mode:
Standard Fan Configuration: 32 dB(A) (idle) / 33 dB(A) (operating)
Redundant Fan Configuration: 33 dB(A) (idle) / 34 dB(A) (operating)
Sound power (LWAd; 1B = 10dB)
Low noise mode:
Standard Fan Configuration: 5.0 B (idle) /  5.0 B (operating)
Redundant Fan Configuration: 5.1 B (idle) /  5.1 B (operating)
Noise notes / description
Noise emissions and operation modes depend on system configuration.
Electrical values
Power supply configuration
1-4x 450 W/800 W hot-plug power supply 
Hot-plug power supply output
450/800 W  (94 % efficiency, 80 PLUS platinum)
Hot-plug power supply redundancy
Yes
Rated voltage range
100 V - 240 V
Rated frequency range
50 Hz - 60 Hz
Rated current in basic configuration
100 V - 240 V /  TBD
Active power (max. configuration)
1070 W
Apparent power (max. configuration)
1080 VA
Heat emission
3852.0 kJ/h (3651.0 BTU/h)
Power Supply Notes
Power Safeguard adapts system performance in case the wattage exceeds supply limits.
http://ts.fujitsu.com/products/standard_servers/e_efficient.html
Compliance
Germany
GS
Europe
CE Class A *
USA/Canada
CSAc/us
FCC Class A
Global
CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)