NEC Intel Xeon E5-2430 N8101-563F User Manual

Product codes
N8101-563F
Page of 258
Intel® Xeon® Processor E5-1600/E5-2600/E5-4600 Product Families
101
Datasheet Volume One
Thermal Management Specifications
5
Thermal Management 
Specifications
5.1
Package Thermal Specifications
The processor requires a thermal solution to maintain temperatures within operating 
limits. Any attempt to operate the processor outside these limits may result in 
permanent damage to the processor and potentially other components within the 
system, see 
. Maintaining the proper 
thermal environment is key to reliable, long-term system operation.
A complete solution includes both component and system level thermal management 
features. Component level thermal solutions can include active or passive heatsinks 
attached to the processor integrated heat spreader (IHS). Typical system level thermal 
solutions may consist of system fans combined with ducting and venting.
This section provides data necessary for developing a complete thermal solution. For 
more information on designing a component level thermal solution, refer to the Intel® 
Xeon® Processor E5-1600/E5-2600/E5-4600 Product Families Thermal/Mechanical 
Design Guide
.
5.1.1
Thermal Specifications
To allow optimal operation and long-term reliability of Intel processor-based systems, 
the processor must remain within the minimum and maximum case temperature 
(T
CASE
) specifications as defined by the applicable thermal profile. Thermal solutions 
not designed to provide sufficient thermal capability may affect the long-term reliability 
of the processor and system. For more details on thermal solution design, please refer 
to the Intel® Xeon® Processor E5-1600/E5-2600/E5-4600 Product Families Thermal/
Mechanical Design Guide
.
The processors implement a methodology for managing processor temperatures which 
is intended to support acoustic noise reduction through fan speed control and to assure 
processor reliability. Selection of the appropriate fan speed is based on the relative 
temperature data reported by the processor’s Platform Environment Control Interface 
(PECI) as described in 
If the DTS value is less than T
CONTROL
, then the case temperature is permitted to 
exceed the Thermal Profile, but the DTS value must remain at or below TCONTROL. 
For T
CASE
 implementations, if DTS is greater than TCONTROL, then the case 
temperature must meet the T
CASE
 based Thermal Profiles. 
For DTS implementations:
• T
CASE
 thermal profile can be ignored during processor run time. 
• If DTS is greater than Tcontrol then follow DTS thermal profile specifications for fan 
speed optimization.