V.- TROUBLE SHOOTING CHART
1.- MOTOR DOES NOT RUN
PROBLEM
POSSIBLE CAUSE
Bad ON-OFF switch.
Replace switch.
Line cord open.
Replace cord.
Motor open.
Check motor and wiring.
There is no voltage line.
Check voltage line. 
2.- LOW SUCTION
PROBLEM
POSSIBLE CAUSE
Full paper bag
replacement
Closed hose or wand
Clean obstruction
Slow motor 
Check carbon brushes
Capped secondary filter
Clean filter
3.- LOW-POWER
PROBLEM
POSSIBLE CAUSE
Suction control dial 
Check position of suction control dial 
Motor damaged
Replace motor 
Bad electrical connection.
Check wiring.
Filters obstructed
Change of filters 
ELECTRICAL CHARACTERISTICS
VOLTAGE
Hz
Amper
127 V ~
60 Hz
11.5