Accu-Tech 012KC8-14130-20 User Manual

Page of 4
Standards
Flame Resistance
NFPA 262 (for plenum, riser 
and general building appli-
cations)
13.13
115
1
1
False
Specifications
General Specifications
Environment
Indoor
Application
General Purpose Horizontal, Vertical Riser, Plenum
Cable Type
Ribbon
Product Type
Distribution
Flame Rating
Plenum (OFNP)
Fiber Category
62.5 µm MM (OM1)
Temperature Range
Storage
-40 °C to 70 °C  (-40 °F to 158 °F)
Installation
0 °C to 60 °C  (32 °F to 140 °F)
Operation
0 °C to 70 °C  (32 °F to 158 °F)
Cable Design
Fiber Count
12
Ribbons per Tube
1
Fibers per Ribbon
12
Fiber Coloring
Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, 
Violet, Rose, Aqua
Buffer Tube Color
Natural
Buffer Tube Diameter
8.1 mm  (0.32 in)
Tape
Water-swellable
Tensile Strength Elements and/or Armoring - Layer 1
Dielectric strength members
Number of Ripcords
2
Outer Jacket Material
Flame-retardant
Outer Jacket Color
Orange
Ribbon Cable, Plenum
12 F, 62.5 µm multimode (OM1)
Product Specification 012KC8-14130-20_NAFTA_AEN
Page 2 | Revision date 2012-08-25