PIOU/PIOUS/RSSU/RSIU Setup
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
128
DKAdmin/DKBackup
DKAdmin/DKBackup PC directly connected to the Strata DK – 50 feet maximum (see 
Figure 16 
on 
Page 130
).
DKAdmin/DKBackup PC connected to Strata DK via Toshiba Data Interface Units – 1000 
feet maximum (see 
Figure 17 
on 
Page 131
).
DKAdmin/DKBackup PC remote modem connected to Strata DK system external 
modem/TTY port (direct modem to modem call)(see 
Figure 18 
on 
Page 132
).
DKAdmin/DKBackup PC remote modem connected to Strata DK system built-in IMDU, 
RMDS (or external modem) – voice call first, then modem to modem connection (see 
Figure 19 
on 
Page 133
).
DKAdmin/DKBackup PC remote modem connected to Strata DK modem pool – then auto 
dial modem pool DIU to Strata DK DIU/TTY port (see 
Figure 20 
on 
Page 135
).
DKAdmin/DKBackup PC DIU/DIU modem pool connected to Strata DK system modem 
– voice call first, then modem to modem connection (see 
Figure 21 
on 
Page 137
).
DKAdmin/DKBackup PC DIU/DIU modem pool connected to Strata DK system modem 
– DIU to DIU connection, then modem to modem connection (see 
Figure 22 
on 
Page 139
).
PIOU/PIOUS/RSSU/RSIU Setup
To check the DKAdmin/DKBackup communications setup
1. From the Options/System Installation/Communication Setup menu, verify that the proper 
COM port is selected and that the communications parameters are set as follows:
2. PIOU or PIOUS PCB installed on Strata DK which is connected to DKAdmin/DKBackup 
PC: if using an IMDU, verify that the switch SW2 is set for 1200 bps (LED CD4 off) and 
that SW3 is set to “MODEM.”
If connecting an external modem, PDIU-DS, or PC COM port directly to the TTY 
modular jack, verify SW2 is set to the “TTY” position.
3. RSSU does not support the IMDU built-in modem or SMDR, and it has no option 
switches. Its communication parameters (TTY port) are always 1200 bps, even parity, 7 
data bits, 1-stop bit.
4. Use Program 03 to identify the PCB slot that contains the PCB with the TTY port or 
modem that will be used (Code 41 for PIOU, PIOUS, or RSSU or Code 49 for RSIU).
5. Use Program 76 if RSIU/RSIS/RMDS is used to connect with the DKAdmin/DKBackup 
PC.
6. Use Program 77-1 (LED 14 and 15) if IMDU or RMDS is used to connect to the 
DKAdmin/DKBackup PC.
Communications port:
COMX (X = 1, 2, 3 or 4)
Baud rate:
1200 (If using RSIU TTY port or RMDS, 
the Baud rate can be higher than 1200 bps.)
Parity:
Even
Data bits:
7
Stop bits:
1