(1. 2) Changing each setting in SS (synchro. scan) mode
(a) Changing the shutter speed setting
1 Set the "
→" to SS by pushing [MENU UP], [MENU DOWN] buttons.
2 Select the shutter speed by pushing [DATA UP], [DATA DOWN] buttons.
(b) Partial scanning setting
1 Set the "
→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2 Select either OFF/120fps/180fps/E.120fps/E.180fps by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The slow shutter speed may increase the fixed pattern noise and/or the white pixels. This is a charac-
teristic of CCD, and is not a symptom of malfunction.
OFF : 1H/525H
↔524H/525H↔OFF↔2FRM↔512FRM
120fps, E.120fps : 1H/262H
↔261H/262H↔OFF↔2FRM↔512FRM
180fps, E.180fps : 1H/175H
↔174H/175H↔OFF↔2FRM↔512FRM
• Sutter mode   MANU, SS, E.TRG
• Synchro. scanning setting
• Partial scanning switch
   OFF/120fps/180fps/E.120fps/E.180fps
-- SHUTTER --
MODE
SS
SS
OFF
PART
OFF
<MODE = SS>
Move up down 
By pushing 
MENU UP, DOWN
Set by pushing
DATA UP, DOWN
IK-TF5C(E)
05.3.14, 14:58